Repeatability and Reproducibility of 4.5 by 4.5 mm Peripapillary Optical Coherence Tomography Angiography Scans in Glaucoma and Non-Glaucoma Eyes.
Alena J Shen, Anna L Urrea, Jae Chang Lee, Bruce Burkemper, Vivian H LeTran, Xiao Zhou, Zhongdi Chu, Dominic J Grisafe, Ali Fard, Brandon Wong, Brian Song, Benjamin Y Xu, Ruikang K Wang, Grace M Richter
Summary
Among nonglaucomatous and glaucomatous eyes, the majority of peripapillary OCTA vessel parameters from 4.5×4.5 mm scans had greater intrasession repeatability than intersession reproducibility.
Abstract
PRCIS
Peripapillary vessel parameters from optical coherence tomography angiography (OCTA) 4.5×4.5 mm scans in nonglaucomatous and glaucomatous eyes showed high repeatability and reproducibility, with higher reliability for commercially developed OCTA parameters compared with custom OCTA parameters.
PURPOSE
The purpose of this study was to assess intrasession repeatability versus intersession reproducibility of peripapillary vessel parameters from 4.5×4.5 mm OCTA scans in nonglaucomatous eyes and glaucomatous eyes.
MATERIALS AND METHODS
In a longitudinal study, peripapillary OCTA scans were quantified using research-oriented custom quantification software that calculated vessel area density (VAD) and flux and clinic-oriented commercially developed software (Cirrus 11.0) that calculated perfusion density (PD) and flux index (FI). Intrasession repeatability and intersession reproducibility were evaluated using within-eye coefficient of variation (CV W ) and intraclass correlation coefficient (ICC).
RESULTS
With 127 nonglaucomatous eyes, intrasession CV W for VAD, PD, flux, and FI were 1.900%, 1.174%, 2.787%, and 1.425%, respectively. The intersession CV W were 2.039%, 1.606%, 4.053%, and 2.798%, respectively. Intrasession ICC ranged from 0.903 to 0.956, and intersession ICC ranged from 0.850 to 0.896. Among 144 glaucomatous eyes, intrasession CV W for VAD, PD, flux, and FI were: 3.841%, 1.493%, 5.009%, and 2.432%, respectively. The intersession CV W were 4.991%, 2.155%, 6.360%, and 3.458%, respectively. Intrasession ICC ranged from 0.956 to 0.969, and intersession ICC ranged from 0.918 to 0.964.
CONCLUSIONS
Among nonglaucomatous and glaucomatous eyes, the majority of peripapillary OCTA vessel parameters from 4.5×4.5 mm scans had greater intrasession repeatability than intersession reproducibility. There was a greater agreement for the commercially developed quantification parameters than for their custom quantification counterparts.
Top Research in OCT & Imaging
Browse all →Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications.
Deep learning in ophthalmology: The technical and clinical considerations.
Anterior segment optical coherence tomography.
Discussion
Comments and discussion will appear here in a future update.