J Cataract Refract Surg
J Cataract Refract SurgDecember 2022Research Support, Non-U.S. Gov't

Long-term effect of canaloplasty on intraocular pressure and use of intraocular pressure-lowering medications in patients with open-angle glaucoma.

Glaucoma SurgeryIOP & Medical Therapy

Summary

Canaloplasty alone or in conjunction with CE with the VISCO360 or OMNI surgical system is a safe, tissue-sparing, and effective minimally invasive glaucoma surgery, using a clear corneal incision in phakic or pseudophakic eyes.

Abstract

PURPOSE

To assess the long-term safety and effectiveness of canaloplasty in reducing intraocular pressure (IOP) and use of IOP-lowering medications in eyes with open-angle glaucoma (OAG).

SETTING

Surgical center (Augencentrum Köln, Köln, Germany).

DESIGN

Retrospective study.

METHODS

206 eyes from 130 patients were included. Canaloplasty was performed using the VISCO360 or OMNI surgical system as a stand-alone procedure in 22 eyes and concomitantly with cataract extraction (CE) in 185 eyes with chronic OAG insufficiently controlled or intolerant to IOP-lowering medications. The number of hypotensive medications and IOP were recorded at baseline, day 1, week 1, month 1, month 3, and every 3 months thereafter, with the last follow-up visit at 36 ± 6 months postoperatively. Patients were stratified by baseline IOP (Group 1, IOP >18 mm Hg; Group 2, IOP ≤18 mm Hg). Treatment success in Group 1 was defined as a reduction in IOP and the use of IOP-lowering medications; Group 2 success was defined as maintenance of a lower IOP and a reduction in medication use.

RESULTS

The preoperative mean IOP of both groups was 21.1 ± 8.8 mm Hg, with a mean of 2.0 ± 0.9 hypotensive medications. The primary success end point was met by 73% of patients, with a mean IOP reduction in Group 1 (131 eyes; 21.8 to 15.6 mm Hg, P < .0001) and a maintenance of IOP control in Group 2 (76 eyes; 15.4 to 13.9 mm Hg, P = .24). Medications decreased from 2.2 ± 0.9 to 0.9 ± 1.1 in Group 1 ( P = .024) and from 1.8 ± 0.8 to 0.7 ± 1.0 in Group 2 ( P = .003).

CONCLUSIONS

Canaloplasty alone or in conjunction with CE with the VISCO360 or OMNI surgical system is a safe, tissue-sparing, and effective minimally invasive glaucoma surgery, using a clear corneal incision in phakic or pseudophakic eyes. Canaloplasty performed with both evaluated devices achieved statistically significant, consistent, and clinically meaningful reductions in IOP and use of IOP-lowering medications in adult patients with OAG. In the consistent cohort (n = 42), the IOP-lowering effect lasted up to 42 months, with ongoing data collection expected to describe long-term effectiveness of this intervention.