Outcomes of Glaucoma Reoperations in the Primary Tube Versus Trabeculectomy Study.
Summary
No significant difference in the rate of reoperation for glaucoma was observed after tube shunt implantation and trabeculectomy with MMC in the PTVT Study.
Abstract
PURPOSE
To describe the incidence and outcomes of reoperations for glaucoma in the Primary Tube Versus Trabeculectomy (PTVT) Study.
DESIGN
Cohort study of patients in a multicenter randomized clinical trial.
PARTICIPANTS
The PTVT Study enrolled 242 patients with medically uncontrolled glaucoma and no previous incisional ocular surgery.
METHODS
Randomization assigned 125 patients to placement of a tube shunt (350-mmBaerveldt glaucoma implant) and 117 patients to trabeculectomy with mitomycin C (MMC, 0.4 mg/ml for 2 minutes). Data were analyzed from patients who underwent additional glaucoma surgery.
MAIN OUTCOME MEASURES
Outcome measures included intraocular pressure (IOP), use of glaucoma medications, visual acuity, surgical complications, and failure (IOP > 21 mmHg or reduced by <20%, IOP ≤ 5 mmHg, additional glaucoma surgery, or loss of light perception vision).
RESULTS
Additional glaucoma surgery was performed in 21 patients in the tube group and 12 patients in the trabeculectomy group in the PTVT Study, and the 5-year cumulative reoperation rate for glaucoma was 18.0% in the tube group and 10.4% in the trabeculectomy group (P = 0.15). Follow-up (mean ± standard deviation [SD]) after additional glaucoma surgery was 35.1 ± 17.7 months in the tube group and 30.1 ± 17.6 months in the trabeculectomy group (P = 0.44). At 3 years after glaucoma reoperation, IOP (mean ± SD) was 15.5 ± 4.8 mmHg in the tube group and 16.6 ± 7.3 mmHg in the trabeculectomy group (P = 0.71). The number of glaucoma medications (mean ± SD) after 3 years of follow-up was 2.1 ± 1.7 in the tube group and 1.7 ± 1.0 in the trabeculectomy group (P = 0.58). The cumulative probability of failure at 3 years after a glaucoma reoperation was 37.8% in the tube group and 21.3% in the trabeculectomy group (P = 0.47).
CONCLUSION
No significant difference in the rate of reoperation for glaucoma was observed after tube shunt implantation and trabeculectomy with MMC in the PTVT Study. Similar surgical outcomes were observed after additional glaucoma surgery, irrespective of the initial procedure to which the patient was randomized. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.
Keywords
More by Sara J Coulon
View full profile →Top Research in Glaucoma Surgery
Browse all →Treatment Outcomes in the Primary Tube Versus Trabeculectomy Study after 1 Year of Follow-up.
Efficacy, Safety, and Risk Factors for Failure of Standalone Ab Interno Gelatin Microstent Implantation versus Standalone Trabeculectomy.
Prospective, Randomized, Controlled Pivotal Trial of an Ab Interno Implanted Trabecular Micro-Bypass in Primary Open-Angle Glaucoma and Cataract: Two-Year Results.
In the Knowledge Library
Discussion
Comments and discussion will appear here in a future update.