Parental Corneal Tomographic and Biomechanical Characteristics of Patients With Keratoconus.
Jie Li, Bi Ning Zhang, Vishal Jhanji, Xiaochuan Wang, Dewei Li, Xianli Du
Summary
Parental corneal tomographic and biomechanical properties of patients with KC suggest a possible predisposition to KC.
Abstract
PURPOSE
To investigate the hereditability of corneal tomographic and biomechanical parameters in keratoconus (KC).
DESIGN
Prospective cohort study.
METHODS
This study was conducted at Qingdao Eye Hospital of Shandong First Medical University in Qingdao, China. Forty-four patients with KC and their biological parents (n = 88) were recruited as the study group. The control group consisted of 84 healthy adults with matched age and gender. Both eyes of each participant underwent clinical examinations, and 1 eye was selected for statistical analysis. Exclusion criteria were as follows: individuals with glaucoma, ocular surgery, systemic diseases known to affect the eyes, or poor cooperation during examination. Subjects were asked to discontinue soft contact lens (CL) wear for 2 weeks and rigid gas permeable CL wear for 4 weeks before ocular examination. All participants underwent a comprehensive assessment including Pentacam Scheimpflug tomography, Corvis ST, visual acuity, refraction examination, axial length, and slitlamp examination for both eyes. Individuals presenting with KC manifestations in at least 1 eye were classified as having KC. A total of 9 Pentacam indices including keratometry in the flat/steep meridian (K1/K2), maximal keratometry (Kmax), thinnest point pachymetry (TP), and maximum/average Ambrósio relational thickness (ARTmax/ARTave), anterior and posterior surfaces elevation of the cornea (Ef/Eb) and total deviation value (Final D), and 21 biomechanical indices were collected. Associations of these factors with KC were evaluated using multiple comparison and binary logistics regression analyses.
RESULTS
Two parents (2.27%) from 2 different families were diagnosed with KC. Parents of patients with KC had thinner corneas with altered corneal biomechanical parameters compared with healthy controls (P < .05). The combined tomographic and biomechanical index demonstrated the highest discriminatory power (area under the receiver operating characteristic curve 0.785) and strong specificity (84.5%). Parental corneal tomographic and biomechanical index, Corvis biomechanical index, and TP were identified as the major influential factors for KC in their offspring by logistic regression analysis, with a 73.3% accuracy in identifying offspring with KC.
CONCLUSIONS
Parental corneal tomographic and biomechanical properties of patients with KC suggest a possible predisposition to KC. A combination of tomography and corneal biomechanics can be helpful in predicting the incidence rate of KC in the offspring of patients with subclinical KC.
Top Research in Cornea & Biomechanics
Browse all →The impact of chronic use of prostaglandin analogues on the biomechanical properties of the cornea in patients with primary open-angle glaucoma.
Corneal Biomechanics and Visual Field Progression in Eyes with Seemingly Well-Controlled Intraocular Pressure.
Evaluation of a New Rebound Self-tonometer, Icare HOME: Comparison With Goldmann Applanation Tonometer.
In the Knowledge Library
Discussion
Comments and discussion will appear here in a future update.