Graefes Arch Clin Exp Ophthalmol
Graefes Arch Clin Exp OphthalmolApril 2024Journal Article

Baseline intraocular pressure: an independent risk factor in severe steroid-induced ocular hypertension after intravitreal dexamethasone implant.

IOP & Medical TherapyEpidemiology & Genetics

Summary

Higher baseline IOP is a risk factor for severe SIOH. Clinicians should be aware of the risk of SIOH when administering steroids intravitreally to patients with high baseline IOP (IOP > 19 mmHg).

Abstract

PURPOSE

To evaluate the baseline intraocular pressure (IOP)-related risk of severe steroid-induced ocular hypertension (SIOH). We hypothesized that the incidence and severity of SIOH may differ according to baseline IOP in patients who received intravitreal dexamethasone implants.

METHODS

A total of 889 eyes treated with intravitreal dexamethasone implants and a baseline IOP of ≤ 23 mmHg were enrolled. Enrolled patients were divided into two groups: the steroid-responders (127 eyes) and the non-steroid-responders (762 eyes). The steroid-responders group was subdivided into post-injection IOP of ≥ 25, > 30, or > 35 mmHg or IOP elevation of ≥ 10 mmHg over the baseline value. The odds ratio of SIOH was calculated using univariable logistic regression analysis, and significant variables were analyzed with a multivariable model. IOP was measured before (baseline IOP) and after dexamethasone implant injection at 1 week and 1, 2, 3, 6, and 12 months.

RESULTS

Although baseline IOP was significantly associated with the development of SIOH in logistic regression analysis, the results from the subgroup analysis differed. In the group with IOP elevation of ≥ 10 mmHg over the baseline, SIOH was not significantly associated with baseline IOP, but it was significantly related to higher baseline IOP in the severe SIOH group (IOP > 30 and > 35 mmHg).

CONCLUSIONS

Higher baseline IOP is a risk factor for severe SIOH. Clinicians should be aware of the risk of SIOH when administering steroids intravitreally to patients with high baseline IOP (IOP > 19 mmHg).

Keywords

Baseline intraocular pressureDexamethasone implantIntraocular pressureRisk factorSteroid-induced ocular hypertension

Discussion

Comments and discussion will appear here in a future update.