Global Search

Search articles, concepts, and chapters

Acta OphthalmolNovember 201033 citations

A study comparing ocular pressure pulse and ocular fundus pulse in dependence of axial eye length and ocular volume.

Berisha Fatmire, Findl Oliver, Lasta Michael, Kiss Barbara, Schmetterer Leopold


AI Summary

This study found pulsatile ocular blood flow measurements are influenced by eye size. Longer eyes show lower pulse amplitudes, suggesting previously reported reduced flow in myopia is an artifact of eye volume, not true blood flow reduction.

Abstract

Purpose

There is a long-standing discussion about whether myopia is associated with decreased choroidal blood flow, as suggested by pneumotonometric measurements of pulsatile ocular blood flow (POBF). However, it has been noted previously that calculations of POBF depend on intraocular volume.

Methods

In the present study we investigated this volume dependence through the comparison of ocular pressure pulse and ocular fundus pulse. Fifty-one healthy participants with different refractive errors participated in the study. Pulse amplitude (PA) and POBF were measured using pneumotonometry. Fundus pulsation amplitude (FPA) was measured with laser interferometry. Axial eye length (AEL) was measured with partial coherence interferometry. A mathematical model was used to calculate choroidal volume changes based on FPA. The ocular pressure pulse was converted into pulse volume (PV) according to the standard procedure used for pneumotonometry.

Results

PA and POBF were found to decrease with increasing axial length (r = -0.55, p < 0.001 and r = -0.57, p < 0.001, respectively). A similar relationship existed for PV (r = -0.57, p < 0.001) and FPA (r = -0.46, p = 0.001). In addition, there was a significant association between PV and choroidal volume change during the cardiac cycle (r = 0.61, p < 0.001).

Conclusion

The present study confirms experimentally that PA, FPA and POBF are dependent on ocular volume and indicates that the pulsatile component of ocular blood flow is not reduced in myopic patients. Accordingly, the relationship between AEL and POBF described previously appears to be a consequence of different ocular volumes. Our findings have important implications for studies using PA or POBF.


MeSH Terms

AdultBlood PressureElasticityEmmetropiaEyeFemaleFundus OculiHumansHyperopiaInterferometryLasersMaleModels, BiologicalMyopiaPulsatile FlowRefractive ErrorsRegional Blood FlowTonometry, OcularYoung Adult

Is this article assigned to the wrong chapter(s)? Let us know.