A study comparing ocular pressure pulse and ocular fundus pulse in dependence of axial eye length and ocular volume.
Berisha Fatmire, Findl Oliver, Lasta Michael, Kiss Barbara, Schmetterer Leopold
AI Summary
This study found pulsatile ocular blood flow measurements are influenced by eye size. Longer eyes show lower pulse amplitudes, suggesting previously reported reduced flow in myopia is an artifact of eye volume, not true blood flow reduction.
Abstract
Purpose
There is a long-standing discussion about whether myopia is associated with decreased choroidal blood flow, as suggested by pneumotonometric measurements of pulsatile ocular blood flow (POBF). However, it has been noted previously that calculations of POBF depend on intraocular volume.
Methods
In the present study we investigated this volume dependence through the comparison of ocular pressure pulse and ocular fundus pulse. Fifty-one healthy participants with different refractive errors participated in the study. Pulse amplitude (PA) and POBF were measured using pneumotonometry. Fundus pulsation amplitude (FPA) was measured with laser interferometry. Axial eye length (AEL) was measured with partial coherence interferometry. A mathematical model was used to calculate choroidal volume changes based on FPA. The ocular pressure pulse was converted into pulse volume (PV) according to the standard procedure used for pneumotonometry.
Results
PA and POBF were found to decrease with increasing axial length (r = -0.55, p < 0.001 and r = -0.57, p < 0.001, respectively). A similar relationship existed for PV (r = -0.57, p < 0.001) and FPA (r = -0.46, p = 0.001). In addition, there was a significant association between PV and choroidal volume change during the cardiac cycle (r = 0.61, p < 0.001).
Conclusion
The present study confirms experimentally that PA, FPA and POBF are dependent on ocular volume and indicates that the pulsatile component of ocular blood flow is not reduced in myopic patients. Accordingly, the relationship between AEL and POBF described previously appears to be a consequence of different ocular volumes. Our findings have important implications for studies using PA or POBF.
MeSH Terms
Shields Classification
Related Articles5
Independent Effects of Axial Length and Intraocular Pressure on the Highly Myopic Optic Nerve Head.
Cross-Sectional StudyIntraocular Pressure and Ocular Perfusion Pressure in Central Serous Chorioretinopathy.
Cross-Sectional StudyThe Strain Response to Intraocular Pressure Increase in the Lamina Cribrosa of Control Subjects and Glaucoma Patients.
Observational StudyAdduction induces large optic nerve head deformations in subjects with normal-tension glaucoma.
Cross-Sectional StudyImpact of Elevated Intraocular Pressure on Lamina Cribrosa Oxygenation: A Combined Experimental-Computational Study on Monkeys.
Basic ScienceIs this article assigned to the wrong chapter(s)? Let us know.