Determinants of image quality of Heidelberg Retina Tomography II and its association with optic disc parameters in a population-based setting.
Zheng Yingfeng, Cheung Carol Y, Wong Tien Y, Wong Wanling, Loon Seng-Chee, Aung Tin
AI Summary
Older age, high myopia, visual impairment, and cataract degrade HRT II image quality, which correlates with smaller optic rim area and deeper cup, impacting glaucoma diagnosis.
Abstract
Purpose
To assess the determinants of image quality of Heidelberg Retina Tomography II (HRT II) and its association with optic disc parameters in a population-based setting.
Design
Population-based, cross-sectional study involving 3280 (78.7% response) Asian Malays aged 40 to 80 years.
Methods
Three thousand fifty-six participants completed the HRT II test. Image quality was assessed using the mean pixel height standard deviation generated by the HRT II, with lower mean pixel height standard deviation indicating higher quality. Participants underwent an interviewer-administered questionnaire and a standardized ophthalmic examination, including visual acuity, applanation tonometry, gonioscopy, refraction, automated perimetry, and lens and fundus photography.
Results
The mean (standard deviation) and median of mean pixel height standard deviation in the study population were 34 (34) and 23 μm respectively. In multivariate regression models, older age and the presence of visual impairment, blindness, high myopia, and cataract were significantly associated with greater mean pixel height standard deviation (P<.05 for all). People with a higher mean pixel height standard deviation were more likely to have smaller rim area and greater cup depth.
Conclusion
People who are older or have high myopia, visual impairment, blindness, or cataract are more likely to have poor HRT II image quality. Poorer image quality is in turn associated with smaller optic rim area and greater cup depth. These data provide useful information when the HRT instrument is used for diagnosing glaucoma in the general population.
MeSH Terms
Shields Classification
Related Articles5
Sleep Disturbance as a Risk Factor for Retinal Neurodegeneration and Subsequent Glaucoma.
Observational StudyComparison of Deep Learning and Clinician Performance for Detecting Referable Glaucoma from Fundus Photographs in a Safety Net Population.
Cohort StudyEarly ophthalmological tumour signs and diagnostic interval in children with brain tumours.
Cohort StudyClinical and anatomical features of myopia.
ReviewCharacterization of Peripapillary Hyperreflective Ovoid Mass-like Structures in a Broad Spectrum of Neurologic Disorders.
Cohort StudyIs this article assigned to the wrong chapter(s)? Let us know.