Glaucoma Journal Club

Ashraf Kazemi

Isfahan University of Medical Sciences · Iranshahr University

In this database

7

2017 – 2026

DB Citations

104

across indexed articles

h-index

20

OpenAlex (all works)

Total Citations

1,686

OpenAlex (all works)

162 total publications (OpenAlex)51 i10-index

7 articles in Glaucoma Journal Club

In Vivo Noninvasive Measurement of Young's Modulus of Elasticity in Human Eyes: A Feasibility Study.

USWE is a novel noninvasive technique for measuring ocular biomechanical properties.

Journal of glaucoma2017 Nov47 citations
iop-medical-therapyglaucoma-surgery

Netarsudil Improves Trabecular Outflow Facility in Patients with Primary Open Angle Glaucoma or Ocular Hypertension: A Phase 2 Study.

Netarsudil acts on the conventional outflow pathway, both proximal and distal, to significantly reduce IOP in POAG and OHT by improving trabecular outflow facility and decreasing EVP.

American journal of ophthalmology2021 Jun41 citations
iop-medical-therapy

Comparison of Corneal Wave Speed and Ocular Rigidity in Normal and Glaucomatous Eyes.

Glaucomatous eyes tend to have lower ocular rigidity than healthy eyes with similar age, IOP, and axial length.

Journal of glaucoma2021 Oct 112 citations
iop-medical-therapy

Eye Dynamics and Engineering Network Consortium: Baseline Characteristics of a Randomized Trial in Healthy Adults.

The current study from the EDEN Consortium describes measurement methods and data analyses with emphasis on IOP variability.

Ophthalmology. Glaucoma20233 citations
iop-medical-therapy

The Effect of Scleral Buckle Surgery on Tonographic Outflow Facility, Positional Intraocular Pressure, and Ocular Biomechanics.

Scleral buckling decreases ocular rigidity but does not affect outflow facility.

Ophthalmology. Glaucoma20241 citations
iop-medical-therapyglaucoma-progression

Assessing Agreement of Intraocular Pressure from Four Mechanistically Different Tonometers in the Eye Dynamics and Engineering Network Clinical Trial.

When adjusted for proparacaine's effect on IOP, 3 tonometers were equivalent between each other when determined by equivalence statistical testing with equivalence bounds ± 2 mmHg.

Ophthalmology. Glaucoma2026
iop-medical-therapycornea-biomechanics

Objective Grading of Tonography Tracings for the Measurement of Outflow Facility.

Objective assessment of pneumatonography tracings can be performed using RMSE of a fitted line and calculation of a predicted quality score that closely matches scores given by expert graders.

Translational vision science & technology2025 Feb 3
iop-medical-therapy