11 articles in Glaucoma Journal Club
The Implications of an Ab Interno Versus Ab Externo Surgical Approach on Outflow Resistance of a Subconjunctival Drainage Device for Intraocular Pressure Control.
The ab interno approach demonstrated greater outflow resistance and less predictable bleb formation than the ab externo approach.
Comparison of Quality and Output of Different Optimal Perimetric Testing Approaches in Children With Glaucoma.
A simple static perimetry approach potentially yields high-quality results in children younger than 10 years.
A Novel Method of Extending Glaucoma Drainage Tube: "Tube-in-Tube" Technique.
Long-Term Safety and Outcomes of β-radiation for Trabeculectomy.
In glaucoma patients at risk of scarring and failure after trabeculectomy, as an antiscarring adjuvant, a 750 cGY dose of β-radiation was found to be safe and efficacious in the long term.
Author Response: Ab Interno versus Ab Externo Surgical Approach on Outflow Resistance of a Subconjunctival Drainage Device.
A Case Report of Complete Blockage of a Baerveldt Glaucoma Implant Following Insertion of a 3-0 Supramid Suture.
We hypothesize that the blockage occurred at the junction between the device tube and plate and that the ballooning phenomenon observed was due to a defect in the tube wall.
A Novel Method of Extending Glaucoma Drainage Tube: "Tube-in-Tube" Technique.
This new "tube-in-tube" glaucoma drainage device tube extension technique is safe and simple to perform, and has many advantages over previously reported techniques.
The Influence of Scleral Flap Thickness, Shape, and Sutures on Intraocular Pressure (IOP) and Aqueous Humor Flow Direction in a Trabeculectomy Model.
We demonstrate a new physical model which shows how changes in scleral flap thickness and shape, and suture number and position affect pressure and flow in a trabeculectomy.
Evaluation of Dimensional and Flow Properties of ExPress Glaucoma Drainage Devices.
The luminal dimensions of the P200 device were 206.4±3.3 and 204.5±0.9 μm at the subconjunctival space and anterior chamber ends, respectively.
Dimensional and Flow Properties of the EX-PRESS Glaucoma Drainage Device.
Long-Term Outcomes of Trabeculectomy Augmented with Mitomycin C Undertaken within the First 2 Years of Life.
A contemporary pediatric trabeculectomy technique augmented with MMC is an effective procedure in the management of glaucoma within the first 2 years of life, as shown by the successful long-term outcomes and low incidence of sight-threatening complications.