Sun Yang
In this database
10
2018 โ 2025
DB Citations
97
across indexed articles
h-index
โ
Not available
Total Citations
โ
Not available
10 articles in Glaucoma Journal Club
Consensus Recommendation for Mouse Models of Ocular Hypertension to Study Aqueous Humor Outflow and Its Mechanisms.
In this review, we describe a set of minimum acceptable standards for developing, characterizing, and utilizing mouse models of open-angle ocular hypertension.
Gender of Award Recipients in Major Ophthalmology Societies.
Overall, women received awards (25.3%) at a higher rate than the average 1970-2020 American gender distributions of ophthalmologists. However, women are still under-represented in many award categories and subspecialties.
Optogenetic Modulation of Intraocular Pressure in a Glucocorticoid-Induced Ocular Hypertension Mouse Model.
Subcellular targeting of inositol phosphatases to remove PIP2 represents a promising strategy to reverse defective TM function in steroid-induced ocular hypertension.
Structural and Metabolic Imaging After Short-term Use of the Balance Goggles System in Glaucoma Patients: A Pilot Study.
There were no significant changes observable using conventional OCT imaging after short-term use of the BGS, although metabolic imaging using FPF may be a useful potential biomarker to complement existing investigations.
Consensus Recommendations for Studies of Outflow Facility and Intraocular Pressure Regulation Using Ex Vivo Perfusion Approaches.
These include: (1) perfused whole globes, (2) stationary anterior segment organ culture, (3) perfused human anterior segment organ culture, (4) perfused animal anterior segment organ culture, (5) perfused human corneal rims, and (6) perfused human anterior segment wedges.
Intraluminal Deposits Found in Glaucoma Tube Shunts Via Anterior Segment Ocular Coherence Tomography.
Anterior segment OCT imaging may be used to evaluate TS integrity. Intraluminal deposits in TS may occur as a natural response to implanted drainage device, possibly as an inflammatory response.
Comparing a Head-Mounted Smartphone Visual Field Analyzer to Standard Automated Perimetry in Glaucoma: A Prospective Study.
Despite advantages in cost and accessibility, the PalmScan head-mounted perimetry device may not be able to fully recapitulate SAP testing.
Influence of Age, Sex, and Wait Times on Public Online Ratings of Glaucoma Physicians in the United States.
Public online ratings of glaucoma specialists in the United States seem to favor those of younger age, men, and those with shorter wait times.
Matrine Reduces Intraocular Pressure in Corticosteroid-Induced Ocular Hypertensive Mouse Eyes.
Matrine decreased the IOP in the DEX-induced OHT mouse model, highlighting its potential as a therapeutic agent for managing glaucoma, particularly in corticosteroid-associated secondary cases.
Safety and Target Engagement of Complement C1q Inhibitor ANX007 in Neurodegenerative Eye Disease: Results from Phase I Studies in Glaucoma.
ANX007 intravitreal injections for glaucoma were well-tolerated and effectively engaged the C1q target, suggesting potential for monthly dosing. This supports further investigation in neurodegenerative eye diseases.