Deep-learning Classifier With an Ultrawide-field Scanning Laser Ophthalmoscope Detects Glaucoma Visual Field Severity.
Despite using an ultrawide-field scanning laser ophthalmoscope, DL can detect glaucoma characteristics and glaucoma visual field defect severity with high reliability.
Comparison of the Intraocular Pressure Measured Using the New Rebound Tonometer Icare ic100 and Icare TA01i or Goldmann Applanation Tonometer.
The new rebound tonometer Icare ic100 almost constantly showed IOPs lower than GAT. The difference was affected by CCT, corneal curvature, and disease.
Evaluation of Automatic Monitoring of Instillation Adherence Using Eye Dropper Bottle Sensor and Deep Learning in Patients With Glaucoma.
The eye dropper bottle sensor system developed by us can be used for automatic monitoring of instillation adherence in patients with glaucoma.
Outcomes of Wider Area Bleb Revision Using Bleb Knife With Adjunctive Mitomycin C.
Wider area bleb revision using bleb knife with adjunctive MMC had a good success rate, according to strict success criteria, except in patients with NVG.
Glaucoma Implant Tube Lumen Obstruction Visualized Using Anterior Segment Optical Coherence Tomography.
We then refixed the tube at the same place and achieved good IOP control after the surgery. Our findings indicate that ASOCT is useful for diagnosing glaucoma implant tube lumen obstruction and surgical decision-making.
Using artificial intelligence to improve human performance: efficient retinal disease detection training with synthetic images.
Synthetic images can be used effectively in medical education. We also found that humans are more robust to novel situations than AI models, thus showcasing human judgement's essential role in medical diagnosis.
A Pilot Evaluation Assessing the Ease of Use and Accuracy of the New Self/Home-Tonometer IcareHOME in Healthy Young Subjects.
The IcareHOME can be used as a self/home-tonometer; however, it may result in lower IOP values.
Intradevice and Interdevice Agreement Between a Rebound Tonometer, Icare PRO, and the Tonopen XL and Kowa Hand-held Applanation Tonometer When Used in the Sitting and Supine Position.
The repeatability of Icare PRO was slightly lower in the supine position than in the sitting position.
Hypotony maculopathy obtained by retro-mode retinal imaging.