Glaucoma Journal Club

In this database

18

2015 – 2024

DB Citations

314

across indexed articles

h-index

Not available

Total Citations

Not available

18 articles in Glaucoma Journal Club

Comparison of Glaucoma Progression Detection by Optical Coherence Tomography and Visual Field.

OCT is more sensitive than VF for the detection of progression in early glaucoma. While the utility of NFL declines in advanced glaucoma, GCC remains a sensitive progression detector from early to advanced stages.

American journal of ophthalmology2017 Dec141 citations
optic-nerveoct-imaging

Baseline Fourier-Domain Optical Coherence Tomography Structural Risk Factors for Visual Field Progression in the Advanced Imaging for Glaucoma Study.

Focal GCC and NFL loss as measured by FDOCT are the strongest predictors for VF progression among the measurements considered.

American journal of ophthalmology2016 Dec60 citations
optic-nervevisual-field

Predictive Factors for the Rate of Visual Field Progression in the Advanced Imaging for Glaucoma Study.

Focal loss measured by FD-OCT or VF along with CCT are strong baseline predictors for the rate of glaucoma progression.

American journal of ophthalmology2019 Jun48 citations
optic-nervevisual-field

Focal Loss Analysis of Nerve Fiber Layer Reflectance for Glaucoma Diagnosis.

Azimuthal filtering reduces the variability of NFL reflectance measurements. Focal NFL reflectance loss has excellent glaucoma diagnostic accuracy compared to the standard NFL thickness parameters. The reflectance map may be useful for localizing NFL defects.

Translational vision science & technology2021 May 316 citations
glaucoma-diagnosisglaucoma-epidemiology

Nerve Fiber Flux Analysis Using Wide-Field Swept-Source Optical Coherence Tomography.

Using an algorithm based on the conservation of flux, we derived nerve fiber trajectories in the peripapillary area.

Translational vision science & technology2018 Feb15 citations
optic-nerveoct-imaging

Sectorwise Visual Field Simulation Using Optical Coherence Tomographic Angiography Nerve Fiber Layer Plexus Measurements in Glaucoma.

OCTA-based simulated VF agreed well with actual 24-2 VF in terms of both the location and severity of glaucoma damage, with the exception of severe glaucoma in which the simulation tended to underestimate severity.

American journal of ophthalmology2020 Apr13 citations
visual-fieldglaucoma-diagnosis

Relating glaucomatous visual field loss to retinal oxygen delivery and metabolism.

Combined measurements of retinal blood flow and oxygen saturation in glaucomatous individuals suggest VF loss is associated with impaired oxygen delivery and augmented OEF.

Acta ophthalmologica2019 Nov12 citations
visual-fieldoct-imaging

Regression-Based Strategies to Reduce Refractive Error-Associated Glaucoma Diagnostic Bias When Using OCT and OCT Angiography.

Myopic eyes are biased to have lower NFLT, GCCT, and NFLP-CD measurements. AL- and SE-based adjustments were effective in mitigating this bias.

Translational vision science & technology2022 Sep 14 citations
oct-imagingoptic-nerve

Relationship Between Macular Vessel Density and Total Retinal Blood Flow in Primary Open-angle Glaucoma.

The finding of an association between macular VD and TRBF supports the role of vascular factors in the pathophysiology of POAG and potential conduct of future studies aimed at identifying multiple image-based vascular metrics for…

Journal of glaucoma2021 Aug 13 citations
visual-fieldoct-imaging

Glaucomatous Focal Perfusion Loss in the Macula Measured by Optical Coherence Tomographic Angiography.

Assessment of macular FPL using OCTA is useful in evaluating glaucomatous damage.

American journal of ophthalmology2024 Dec2 citations
oct-imagingglaucoma-diagnosis

Differentiating Multiple Sclerosis and Glaucoma With Sectoral Pattern Analysis of Peripapillary Nerve Fiber Layer.

Normalizing NFL reduction as a percentage of normal reference accentuated patterns characteristic of MS and glaucoma. Quantitative pattern indexes were effective in differentiating the two diseases.

Translational vision science & technology2024 Nov 4
optic-nerveoct-imaging

Sector-Based Regression Strategies to Reduce Refractive Error-Associated Glaucoma Diagnostic Bias When Using OCT and OCT Angiography.

The effect of optical magnification is even more prominent among sectors than the global parameters. AL- and SE-based adjustments should be individualized to each sector to mitigate this magnification bias effectively.

Translational vision science & technology2023 Sep 1
oct-imagingoptic-nerve

Regression Analysis of Optical Coherence Tomography Disc Variables for Glaucoma Diagnosis.

Our various regression approaches were not able to significantly improve disc-based OCT glaucoma diagnosis.

Journal of glaucoma2016 Aug
optic-nerveoct-imaging

Glaucoma Increases Retinal Surface Contour Variability as Measured by Optical Coherence Tomography.

Retinal surface contour variability was significantly increased in glaucoma patients.

Investigative ophthalmology & visual science2016 Jul 1
visual-fieldoct-imaging

Longitudinal and Cross-Sectional Analyses of Age Effects on Retinal Nerve Fiber Layer and Ganglion Cell Complex Thickness by Fourier-Domain OCT.

Longitudinal and cross-sectional analyses provided consistent rates of approximately 0.2% per year of age-related thinning in NFL and GCC thicknesses.

Translational vision science & technology2016 Mar
iop-medical-therapyoptic-nerve

Predicting Development of Glaucomatous Visual Field Conversion Using Baseline Fourier-Domain Optical Coherence Tomography.

Reductions in NFL and GCC thickness can predict the development of glaucomatous VF loss in glaucoma suspects and preperimetric glaucoma patients.

American journal of ophthalmology2016 Mar
optic-nerveoct-imaging

Effect of Signal Intensity on Measurement of Ganglion Cell Complex and Retinal Nerve Fiber Layer Scans in Fourier-Domain Optical Coherence Tomography.

Repeatability of RNFL and GCC thickness measurements may be improved by excluding images with cropped anatomic features and weak signal strength below recommended SSI cutoffs.

Translational vision science & technology2015 Oct
optic-nerveoct-imaging

Combining measurements from three anatomical areas for glaucoma diagnosis using Fourier-domain optical coherence tomography.

Combining structural measurements of GCC, NFL and disc variables from FD-OCT created a GSDI that improved the accuracy for glaucoma diagnosis.

The British journal of ophthalmology2015 Sep
glaucoma-diagnosisoptic-nerve