Effect of Signal Intensity on Measurement of Ganglion Cell Complex and Retinal Nerve Fiber Layer Scans in Fourier-Domain Optical Coherence Tomography.
Summary
Repeatability of RNFL and GCC thickness measurements may be improved by excluding images with cropped anatomic features and weak signal strength below recommended SSI cutoffs.
Abstract
PURPOSE
We determined the effect of Fourier-domain optical coherence tomography (OCT) signal strength index (SSI) and cropping on retinal nerve fiber layer (RNFL) and macular ganglion cell complex (GCC) scan repeatability and measurement thickness.
METHODS
Eyes were enrolled in the longitudinal Advanced Imaging for Glaucoma Study. At each visit, three repeat scans from the optic nerve head and macular protocols were obtained. Each measurement was associated with an SSI value from 0 to 100. Measurements with similar SSI scores were grouped to calculate repeatability defined as pooled standard deviation. Within-visit analysis was used to determine how measured thickness changed in relation to change in SSI level.
RESULTS
The study included 1130 eyes of 569 patients. Cropped images yielded significantly worse repeatability and they were excluded from subsequent analyses. The within-visit repeatability for RNFL and GCC measurements were significantly better with higher signal strength, and optimal cutoffs were SSI ≥ 37 and ≥ 44, respectively. The coefficient of variation was <1.8% for RNFL scans with SSI ≥ 37 and < 2% for GCC with SSI ≥ 44. For scans above the cutoff SSI, higher SSI's were correlated with thicker RNFL among normal (slope = 0.056 μm/SSI unit,< 0.001) eyes and glaucoma suspect and perimetric glaucoma (GSPPG) eyes (slope = 0.060 μm/SSI unit,< 0.001), but not for perimetric glaucoma (PG) eyes. No significant correlation was found for GCC.
CONCLUSION
Repeatability of RNFL and GCC thickness measurements may be improved by excluding images with cropped anatomic features and weak signal strength below recommended SSI cutoffs.
TRANSLATIONAL RELEVANCE
Measurement precision and image quality of inner eye structure by advanced imaging modality are important for clinical diagnosis and tracking of glaucoma disease.
Keywords
More by Xinbo Zhang
View full profile →Comparison of Glaucoma Progression Detection by Optical Coherence Tomography and Visual Field.
Baseline Fourier-Domain Optical Coherence Tomography Structural Risk Factors for Visual Field Progression in the Advanced Imaging for Glaucoma Study.
Predictive Factors for the Rate of Visual Field Progression in the Advanced Imaging for Glaucoma Study.
Top Research in Optic Nerve & Disc
Browse all →Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Discussion
Comments and discussion will appear here in a future update.