Tanito Masaki
In this database
39
2015 – 2026
DB Citations
460
across indexed articles
h-index
—
Not available
Total Citations
—
Not available
39 articles in Glaucoma Journal Club
Short-term results of microhook ab interno trabeculotomy, a novel minimally invasive glaucoma surgery in Japanese eyes: initial case series.
Microhook trabeculotomy normalizes the IOP during the early postoperative period in patients with glaucoma.
Validation of a Deep Learning Model to Screen for Glaucoma Using Images from Different Fundus Cameras and Data Augmentation.
The previously developed deep residual learning algorithm achieved high diagnostic performance with different fundus cameras across multiple institutes, in particular when image augmentation was used.
Effects of Study Population, Labeling and Training on Glaucoma Detection Using Deep Learning Algorithms.
Deep learning glaucoma detection can achieve high accuracy across diverse datasets with appropriate training strategies.
Influence of Goniotomy Size on Treatment Safety and Efficacy for Primary Open-Angle Glaucoma: A Multicenter Study.
120GT, 240GT, and 360GT with or without PEI showed similar efficacy in reducing IOP and medications used in POAG.
Investigating the usefulness of a cluster-based trend analysis to detect visual field progression in patients with open-angle glaucoma.
Cluster-based trend analysis and mTD trend analysis results were significantly associated in all clusters and with all lengths of VF series.
Predicting the Glaucomatous Central 10-Degree Visual Field From Optical Coherence Tomography Using Deep Learning and Tensor Regression.
The Humphrey 10-2 VF can be predicted from OCT-measured retinal layer thicknesses using deep learning and tensor regression.
Predicting 10-2 Visual Field From Optical Coherence Tomography in Glaucoma Using Deep Learning Corrected With 24-2/30-2 Visual Field.
The performance of a DL model to predict 10-2 VF from macular OCT was improved by the correction with HFA 24-2/30-2.
Validating Variational Bayes Linear Regression Method With Multi-Central Datasets.
VBLR outperformed OLSLR to predict future VF progression, and the VBLR has a potential to be a helpful tool at clinical settings.
Persistent Hypotony and Annular Ciliochoroidal Detachment After Microhook Ab Interno Trabeculotomy.
All patients had open-angle glaucoma (2 juvenile, 1 primary, and 1 pigmentary) and were myopic (axial lengths, >24 mm).
Surgical Results of Trabeculectomy among Groups Stratified by Prostaglandin-Associated Periorbitopathy Severity.
The preoperative presence of severe PAP worsens the 1-year success rate of LEC in patients with POAG.
Noninferiority of Microhook to Trabectome: Trabectome versus Ab Interno Microhook Trabeculotomy Comparative Study (Tram Trac Study).
Surgical success of μTLO at 1 year after was not inferior to that of Trabectome surgery.
Effects of ocular and systemic factors on the progression of glaucomatous visual field damage in various sectors.
Smoking status is related to glaucomatous VF progression in all sectors of the inferior hemifield.
A case of bilateral deep stromal corneal opacity and vascularization after use of multiple antiglaucoma medications including brimonidine tartrate ophthalmic solution.
Different patterns in the corneal endothelial cell loss after pars plana and pars limbal insertion of the Baerveldt glaucoma implant.
CE loss in the PL and PP cohorts was biphasic and unidirectional, respectively.
Histologic Findings of Trabecular Meshwork and Schlemm's Canal After Microhook Ab Interno Trabeculotomy.
DISCUSSION: The μLOT cleft can appear as both incisional and excisional patterns. In addition to incremental conventional outflow with reduced TM resistance, another unconventional outflow may be a mechanism of IOP reduction after LOT procedures.
Validation of formula-predicted glaucomatous optic disc appearances: the Glaucoma Stereo Analysis Study.
The GSAS classification formula can predict and quantify each component of different optic disc appearances in each eye and provide a novel parameter to describe glaucomatous optic disc characteristics.
Effect of Toric Intraocular Lens Implantation on Visual Acuity and Astigmatism Status in Eyes Treated With Microhook Ab Interno Trabeculotomy.
Better visual outcomes may be achieved with toric IOLs when a combined MIGS/cataract surgery is performed in eyes with corneal astigmatism.
Comparison of Schlemm's Canal Morphology Parameters Between Propensity Score-Matched Primary Open-Angle Glaucoma and Exfoliation Glaucoma.
These findings suggest that in EXG, SCE loss occurs independently of background factors such as aging and medication use.
Flow Pressure Characteristics of the Ahmed Glaucoma Valve and Possible Effect of Entrapped Air in the Tube.
Air in the AGV tube causes increased repriming pressure of about two-fold compared to repriming without air.
Surgical Results of Ahmed Glaucoma Valve Implantation in One-chamber Eyes.
Choice of pars plana AGV tube insertion with simultaneous vitrectomy is reasonable to achieve IOP reduction and minimize vision-threatening complication in glaucomatous eyes with a damaged iris-lens diaphragm.
Agreement Analysis on Angle Characteristics With Automated Gonioscopy.
Our study shows that automated gonioscopy provides moderate agreement on most clinically relevant features. Binary characteristics such as angle opening or PAS seem to be more robust than more complex angle classification parameters.
Report of a Cluster of Cases of Toxic Anterior-segment Syndrome After Implantation of a Specific Intraocular Lens Model.
We experienced a cluster of TASS cases in eyes implanted with the Lentis Comfort/LS-313 MF15 IOL in a short period of time.
Automated Focal Plane Merging From a Stack of Gonioscopic Photographs Using a Focus-Stacking Algorithm.
Focal plane merging by the automated algorithm can make the gonio-images deeper focus compared with the paired best-focused images subjectively and objectively, which would be useful for angle pathological assessment in clinical practice.
Improving Visual Field Trend Analysis with OCT and Deeply Regularized Latent-Space Linear Regression.
It is useful to include OCT measurements when predicting future VF progression in glaucoma patients, especially with short VF series.
Impact of prostaglandin-associated periorbitopathy on surgical outcomes of trabeculectomy and ahmed glaucoma valve implantation.
PAP severity should be considered when selecting a surgical approach for glaucoma.
Effect of first-line and second-line selective laser trabeculoplasty on corneal hysteresis in patients with normal tension glaucoma: a multicenter study.
The First-line or Second-line Selective Laser Trabeculoplasty (FSS) Study demonstrated that SLT is an effective and safe treatment for patients with normal tension glaucoma (NTG).
In Vitro Analysis of Pressure Resistance in the Paul Glaucoma Implant and Ahmed ClearPath 250 With and Without Polypropylene Thread Inside the Tube.
Inserting polypropylene threads into the tubes of nonvalved glaucoma drainage devices significantly affects pressure resistance with various degree.
Clinical parameters associated with blood pressure in patients with primary open-angle glaucoma and exfoliation glaucoma.
The increased BP variability observed in EXG patients may be attributable to systemic manifestations of exfoliation syndrome.
Response to the letter to the editor regarding "Clinical parameters associated with blood pressure in patients with primary open-angle glaucoma and exfoliation glaucoma".
Effects of Daily Ambient Temperature on Intraocular Pressure: A Time-Series Analysis Using Generalized Additive and Distributed Lag Nonlinear Models.
Ambient temperature may be associated with IOP through nonlinear relationships and short-term cumulative effects, particularly in the non-glaucoma group. These findings suggest that monitoring ambient temperature is important for IOP management.
Long-term corneal endothelial cell loss after filtration surgery: analysis using natural language processing.
Long-term ECD loss occurs progressively after filtration surgery, with lower postoperative IOP emerging as a risk factor.
The Usefulness of Inclusion of Visual Field Tests Using Multiple Testing Strategies in Perimetric Rate of Progression Analyses.
It is useful to add information from prior SITA Fast VFs when conducting mTD trend analysis with SITA Standard VFs.
A Novel Approach To Predict Glaucomatous Impairment in the Central 10° Visual Field, Excluding the Effect of Cataract.
Accurate prediction of genuine glaucomatous VF impairment was achieved using pointwise TD with RFM. No merit was observed by incorporating the GCIPL into this model.
Original vs Shoji Edition of Tanito Microhook Trabeculotomy Combined with Cataract Surgery: Comparative Clinical Outcomes.
Both versions of TMH trabeculotomy combined with cataract surgery demonstrated acceptable mid-term surgical success and safety profiles. The Shoji edition, designed to improve access and usability, may offer advantages in certain surgical settings.
Comparison of 1-year effectiveness between phaco-microhook ab-interno trabeculotomy and phaco-iStent trabecular micro-bypass stent in primary open-angle glaucoma with low-teen intraocular pressure.
Both phaco-µLOT and phaco-iStent hold promise in reducing the need for antiglaucoma medications in POAG eyes with low-teen IOP. Phaco-µLOT may be more effective than phaco-iStent in controlling IOP.
Microhook ab interno trabeculotomy, a novel minimally invasive glaucoma surgery, in eyes with open-angle glaucoma with scleral thinning.
Evaluation of Glaucoma Progression in Large-Scale Clinical Data: The Japanese Archive of Multicentral Databases in Glaucoma (JAMDIG).
Age and the degree of VF damage were related to future progression.
Estimation of the Disc Damage Likelihood Scale in primary open-angle glaucoma: the Glaucoma Stereo Analysis Study.
The DDLS obtained through three-dimensional ONH analysis correlates well with the severity of glaucomatous ONH and visual field damage.
Possible bidirectional flow of aqueous fluid after Baerveldt glaucoma implant surgery.