Macula Ganglion Cell Thickness Changes Display Location-Specific Variation Patterns in Intermediate Age-Related Macular Degeneration.
Trinh Matt, Tong Janelle, Yoshioka Nayuta, Zangerl Barbara, Kalloniatis Michael, Nivison-Smith Lisa
AI Summary
Intermediate AMD eyes showed non-uniform macula ganglion cell layer changes, with more thickening than thinning, varying by location. This aids understanding and monitoring GCL pathologies.
Abstract
Purpose
The purpose of this study was to examine changes in the ganglion cell layer (GCL) of individuals with intermediate age-related macular degeneration (AMD) using grid-wise analysis for macular optical coherence tomography (OCT) volume scans. We also aim to validate the use of age-correction functions for GCL thickness in diseased eyes.
Methods
OCT macular cube scans covering 30° × 25° were acquired using Spectralis spectral-domain OCT for 87 eyes with intermediate AMD, 77 age-matched normal eyes, and 254 non-age-matched normal eyes. The thickness of the ganglion cell layer (GCL) was defined after segmentation at 60 locations across an 8 × 8 grid centered on the fovea, where each grid location covered 0.74 mm2 (approximately 3° × 3°) within the macula. Each GCL location of normal eyes (n = 77) were assigned to a specific iso-ganglion cell density cluster in the macula, based on patterns of age-related GCL thickness loss. Analyses were then performed comparing AMD GCL grid-wise data against corresponding spatial clusters, and significant AMD GCL thickness changes were denoted as values outside the 95% distribution limits.
Results
Analysis of GCL thickness changes revealed significant differences between spatial clusters, with thinning toward the fovea, and thickening toward the peripheral macula. The direction of GCL thickness changes in AMD were associated more so with thickening than thinning in all analyses. Results were corroborated by the application of GCL thickness age-correction functions.
Conclusions
GCL thickness changed significantly and nonuniformly within the macula of intermediate AMD eyes. Further characterization of these changes is critical to improve diagnoses and monitoring of GCL-altering pathologies.
MeSH Terms
Shields Classification
Key Concepts5
Analysis of GCL thickness changes in intermediate age-related macular degeneration (AMD) eyes revealed significant differences between spatial clusters, with thinning toward the fovea, and thickening toward the peripheral macula.
The direction of ganglion cell layer (GCL) thickness changes in intermediate age-related macular degeneration (AMD) eyes were associated more with thickening than thinning in all analyses.
Ganglion cell layer (GCL) thickness changed significantly and nonuniformly within the macula of intermediate age-related macular degeneration (AMD) eyes.
Optical coherence tomography (OCT) macular cube scans covering 30° × 25° were acquired for 87 eyes with intermediate age-related macular degeneration (AMD), 77 age-matched normal eyes, and 254 non-age-matched normal eyes.
The thickness of the ganglion cell layer (GCL) was defined after segmentation at 60 locations across an 8 × 8 grid centered on the fovea, where each grid location covered 0.74 mm2 (approximately 3° × 3°) within the macula.
Related Articles5
Longitudinal Changes of Retinal Nerve Fiber Layer and Ganglion Cell-Inner Plexiform Layer in Highly Myopic Glaucoma: A 3-Year Cohort Study.
Cohort StudyIndependent Evaluation of RETFound Foundation Model's Performance on Optic Nerve Analysis Using Fundus Photography.
Observational StudyProximal Location of Optic Disc Hemorrhage and Glaucoma Progression.
Cohort StudyPrediction of Visual Field Progression with Baseline and Longitudinal Structural Measurements Using Deep Learning.
Observational StudyNumber of macula optical coherence tomography scans needed to detect glaucoma progression.
Cohort StudyIs this article assigned to the wrong chapter(s)? Let us know.