PURPOSE
To evaluate the ability of the neuroretinal rim (NRR) rules determined using spectral domain optical coherence tomography (SDOCT) in diagnosing glaucoma and to study the effect of optic disc size and disease severity on the diagnostic ability of these rules.
METHODS
In a cross-sectional study, 125 eyes of 96 glaucoma patients and 96 eyes of 72 control subjects underwent optic nerve head (ONH) imaging with SDOCT. Inferior (I), superior (S), nasal (N) and temporal (T) NRR areas were automatically determined by the sdoct software. Diagnostic abilities of ISNT (I > S > N > T), IT (I > T) and ST (S > T) rules in glaucoma were evaluated using sensitivity, specificity and likelihood ratios (LR). Effect of optic disc size and disease severity [based on mean deviation (MD) on visual fields] on the diagnostic ability of the NRR rules was evaluated using regression models.
RESULTS
Sensitivities of ISNT, IT and ST rules were 80.8%, 60.0% and 29.6%, respectively, and the specificities were 32.3%, 84.4% and 93.8%, respectively. Positive LRs of ISNT, IT and ST rules were 1.19, 3.84 and 4.74, respectively, and negative LRs were 0.60, 0.47 and 0.75, respectively. Sensitivities of ISNT (coefficient: -1.06, p = 0.02) and IT (-0.71, 0.05) rules decreased with increasing disc size. Positive LR of IT rule increased significantly (-0.01, 0.04) with decreasing MD, and negative LR of IT rule decreased (got better) significantly (0.26, 0.05) with decreasing disc size.
CONCLUSIONS
Neuroretinal rim rules, as determined by SDOCT, do not allow robust differentiation of glaucomatous from non-glaucomatous discs.
Keywords
More by Harsha L Rao
View full profile →Regional Comparisons of Optical Coherence Tomography Angiography Vessel Density in Primary Open-Angle Glaucoma.
Prospective Evaluation of Standalone XEN Gel Implant and Combined Phacoemulsification-XEN Gel Implant Surgery: 1-Year Results.
Diagnostic ability of peripapillary vessel density measurements of optical coherence tomography angiography in primary open-angle and angle-closure glaucoma.
Top Research in Optic Nerve & Disc
Browse all →Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Discussion
Comments and discussion will appear here in a future update.