Garudadri Chandra S
In this database
18
2015 โ 2021
DB Citations
66
across indexed articles
h-index
โ
Not available
Total Citations
โ
Not available
18 articles in Glaucoma Journal Club
Comparison of the New Low-Cost Nonvalved Glaucoma Drainage Device with Ahmed Glaucoma Valve in Refractory Pediatric Glaucoma in Indian Eyes.
In refractory pediatric glaucoma, both AGV and AADI showed similar qualified success and complication rates at 1 and 3 years.
Outcomes of Silicone Ahmed Glaucoma Valve Implantation in Refractory Pediatric Glaucoma.
AGV implantation had good success rate in refractory pediatric glaucoma. The success rates were similar in PCG and SPG as were the complications. Number of prior intraocular surgeries was a risk factor for failure.
Comparison of Saccadic Eye Movements Among the High-tension Glaucoma, Primary Angle-closure Glaucoma, and Normal-tension Glaucoma.
Saccadic eye movement parameters were differently affected among the glaucoma subtypes. Saccadic parameters were more affected in NTG.
Intermediate Term Outcomes of Early Posttrabeculectomy Bleb Leaks Managed by Large Diameter Soft Bandage Contact Lens.
Large diameter BCL was effective in the management of early bleb leak with good intermediate term success for IOP control.
Modifications to Combined Trabeculectomy and Manual Small Incision Cataract Surgery: Outcomes and Adaptability in Resource-constrained Areas.
We present a straightforward, yet effective technique of combined cataract and glaucoma surgery. The technique has a potential for wider applicability, especially in the underserved regions of the world.
Re: Yu et al.: Risk of visual field progression in glaucoma patients with progressive retinal nerve fiber layer thinning (Ophthalmology. 2016;123:1201-1210).
Outcomes of Primary Trabeculectomy With Mitomycin-C in Glaucoma Secondary to Iridocorneal Endothelial Syndrome.
Primary trabeculectomy with MMC offers moderate surgical success in patients with ICE syndrome. Maintaining long-term IOP control and corneal clarity in these eyes is a big challenge.
Comparison of Cataract Surgery Alone Versus Cataract Surgery Combined With Trabeculectomy in the Management of Phacomorphic Glaucoma.
In our cohort of phacomorphic glaucoma presenting within 4 weeks of onset, cataract surgery and combined surgery resulted in similar IOP control at 6 months.
Diagnostic Abilities of Variable and Enhanced Corneal Compensation Algorithms of GDx in Different Severities of Glaucoma.
In scans satisfying the manufacturer-recommended quality parameters, which were significantly greater with ECC than VCC algorithm, diagnostic abilities of GDx ECC and VCC in glaucoma were similar.
Comparing the Structure-Function Relationship at the Macula With Standard Automated Perimetry and Microperimetry.
Visual sensitivity measurements of both SAP and MP demonstrated a similar relationship with the GCIPL measurements of SDOCT at the macula in glaucoma.
Re: Peters et al.: Threat to fixation at diagnosis and lifetime risk of visual impairment in open-angle glaucoma (Ophthalmology 2015;122:1034-9).
Reference Standard Test and the Diagnostic Ability of Spectral Domain Optical Coherence Tomography in Glaucoma.
Diagnostic parameters of SDOCT that was significantly affected by reference standard was the specificity, which was greater with optic disc classification as the reference standard.
Structure-Function Relationship in Glaucoma Using Ganglion Cell-Inner Plexiform Layer Thickness Measurements.
Significant structure-function associations were found between GCIPL thickness measurements at the macula and the functional loss measured on 10-2 SAP in glaucoma.
The ISNT rule in glaucoma: revisiting with spectral domain optical coherence tomography.
Neuroretinal rim rules, as determined by SDOCT, do not allow robust differentiation of glaucomatous from non-glaucomatous discs.
Re: Charlson et al.: Nocturnal systemic hypotension increases the risk of glaucoma progression (Ophthalmology 2014;121:2004-12).
Atypical birefringence pattern and the diagnostic ability of scanning laser polarimetry with enhanced corneal compensation in glaucoma.
Diagnostic performances of TSNIT and inferior average RNFL parameters with ECC protocol of SLP were significantly influenced by TSS even when the TSS values were within the acceptable limits.
Role of visual field reliability indices in ruling out glaucoma.
This study suggests that FN response rates have an effect on the ability of automated VF assessments to rule out glaucoma.
Comparing spectral-domain optical coherence tomography and standard automated perimetry to diagnose glaucomatous optic neuropathy.
Most of the RNFL and GCC parameters of SDOCT had better sensitivities and negative LRs to diagnose GON compared with SAP.