Senthil Sirisha
In this database
45
2015 – 2025
DB Citations
240
across indexed articles
h-index
—
Not available
Total Citations
—
Not available
45 articles in Glaucoma Journal Club
Comparison of the New Low-Cost Nonvalved Glaucoma Drainage Device with Ahmed Glaucoma Valve in Refractory Pediatric Glaucoma in Indian Eyes.
In refractory pediatric glaucoma, both AGV and AADI showed similar qualified success and complication rates at 1 and 3 years.
Comparison of Visual Field Progression Rates Among the High Tension Glaucoma, Primary Angle Closure Glaucoma, and Normal Tension Glaucoma.
In our cohort of treated primary glaucoma with matched baseline severity, a greater proportion of HTG eyes progressed faster compared to PACG.
Outcomes of Silicone Ahmed Glaucoma Valve Implantation in Refractory Pediatric Glaucoma.
AGV implantation had good success rate in refractory pediatric glaucoma. The success rates were similar in PCG and SPG as were the complications. Number of prior intraocular surgeries was a risk factor for failure.
Outcomes of lensectomy and risk factors for failure in spherophakic eyes with secondary glaucoma.
Lensectomy was effective in controlling IOP in close to half of all eyes with spherophakia and secondary glaucoma, 40% eyes needed AGM and only 7.7% eyes needed glaucoma surgery for IOP control.
A Rare Case of Pupillary Block Glaucoma Following CentraFLOW Implantable Collamer Lens Surgery.
By 1 month, the visual acuity was 20/30 with an IOP of 14 mm Hg, which was maintained at 1-year follow-up.
"Pseudophakic Reverse Pupillary Block" Following Yamane Technique Scleral-fixated Intraocular Lens.
The present case describes a rare complication of "pseudophakic reverse pupillary block" after a glued SFIOL implantation.
Comparison of Saccadic Eye Movements Among the High-tension Glaucoma, Primary Angle-closure Glaucoma, and Normal-tension Glaucoma.
Saccadic eye movement parameters were differently affected among the glaucoma subtypes. Saccadic parameters were more affected in NTG.
Determinants of Optical Coherence Tomography Parameters in a Population-based Study.
Age, sex, AXL, disc area, and signal strength of the scan were significantly associated with OCT measurements. These factors may need to be considered while interpreting the OCT parameters in pathologic conditions such as glaucoma.
Outcomes of Ahmed Glaucoma Drainage Implant in Eyes With Glaucoma Secondary to Iridocorneal Endothelial Syndrome.
AGV implant was reasonably successful for IOP control in glaucoma secondary to ICE syndrome with a few common but manageable corneal complications.
Clinical Presentation and Management Outcomes of Coexistent Congenital Glaucoma and Retinopathy of Prematurity.
Out of 15,000 premature-infants in the database, 3000 children had ROP, and of these 87 eyes of 57 premature children had glaucoma.
Outcomes of Descemet-Stripping Endothelial Keratoplasty in 52 Eyes With Iridocorneal Endothelial Syndrome.
In this study, DSEK had a success rate of ∼60% at 5 years.
Is Ahmed Glaucoma Valve Consistent in Performance?
The device showed functionality like a valve. The resistance during priming did not affect opening and closing pressures of the AGV. This study showed variable in vitro performance of the AGV.
Profile of Newly Diagnosed Childhood Glaucoma in India: Indian Childhood Glaucoma Study (ICGS) Group 1.
Our study has one of the largest numbers of consecutive children with glaucoma classified according to the CGRN classification.
Premature Expression of Pseudoexfoliation Syndrome With Presenile Cataract in a 28-Year-Old Lady.
The present case is the first to describe the unusual presentation of pseudoexfoliation in a young individual along with presenile cataract.
Outcomes of Gonioscopy-Assisted Transluminal Trabeculotomy in Eyes With Prior Failed Glaucoma Surgery.
This study concludes that GATT can be an effective and safe surgical alternative for managing IOP in eyes with prior failed glaucoma surgeries, associated with minimal complications.
Comparison of Rebound Tonometry and Handheld Applanation Tonometry in Pediatric Glaucoma with Clear and Scarred Corneas.
Outcomes of Bleb Repair for Delayed Bleb Leaks and Sweating Blebs.
Higher complication rate before bleb repair in eyes with sweating bleb warrants early bleb repair. Bleb repair helped retain bleb function in majority of the eyes with sweating blebs, strengthening our recommendation.
Treatment Outcomes of Primary Combined Trabeculotomy With Trabeculectomy in Early Onset Glaucoma With Sturge-Weber Syndrome.
CTT as a primary procedure showed good long-term efficacy and safety in SWS with early onset glaucoma.
Malignant Glaucoma Post Gonioscopy-Assisted Transluminal Trabeculectomy.
This is a rare sight-threatening complication following gonioscopy-assisted transluminal trabeculotomy .
Glaucoma Evaluation and Management in Eyes With Boston Type 1 and Aurolab Keratoprostheses in an Indian Cohort.
Glaucoma was seen in more than half of the eyes with type 1 keratoprosthesis.
Outcomes of Ahmed Glaucoma Valve Implantation in Eyes with Pediatric Keratoplasty.
In this cohort, the long-term AGV success and graft survival outcomes are satisfactory considering that AGV was performed in complex eyes with keratoplasty.
Outcomes of Primary Combined Trabeculotomy and Trabeculectomy in Early-Onset Glaucoma in Children with Congenital Aniridia.
CTT showed good success in children with congenital aniridia with early-onset glaucoma.
Intermediate Term Outcomes of Early Posttrabeculectomy Bleb Leaks Managed by Large Diameter Soft Bandage Contact Lens.
Large diameter BCL was effective in the management of early bleb leak with good intermediate term success for IOP control.
Clinical Insights Into a Large Cohort of Phakomatosis Pigmentovascularis.
Phakomatosis cesioflammea (Type iib) was the most common subgroup noted.
False Passage of 5-0 Polypropylene Suture into Episcleral Vein during Gonioscopy-Assisted Transluminal Trabeculotomy.
Through this case report, we describe a rare complication where the suture had traversed through a dilated episcleral vein during GATT. To our knowledge, there has been no prior report of such a complication.
Effect of Intravenous Dexmedetomidine on Intraocular Pressure in Patients Undergoing Glaucoma Surgery Under Local Anesthesia: A Pilot Study.
In the small sample of (ASA I-II) patients studied, preoperative dexmedetomidine produced a significant drop in IOP (33%) within 15 minutes of IV administration in patients with glaucoma that was reversing at 2 hours, with…
Progressive High Hypermetropic Shift as a Refractive Surprise Following Glaucoma Filtration Surgery in a Phakic Child With Early-Onset Childhood Glaucoma Associated With Axenfeld-Rieger Anomaly.
Present case is the first to describe the unusual presentation of progressive high hypermetropia in a child with Axenfeld- Rieger anomaly with congenital glaucoma after surgical intervention for glaucoma.
Meta-Analysis of Association of Obstructive Sleep Apnea (OSA) With Glaucoma.
Phacomatosis Pigmentovascularis and Sturge-Weber Syndrome: Comparative Outcomes of Primary Combined Trabeculotomy with Trabeculectomy.
Primary CTT achieved good long-term IOP control in both the PPV and SWS groups.
Intermediate-Term Outcomes and Complications of Ahmed Glaucoma Valve in Type 1 Keratoprostheses.
Ahmed glaucoma valve implantation offered promising results in managing glaucoma in eyes with type 1 KPro, particularly in relatively young Indian population. However, close monitoring for tube-related complications and glaucoma progression is warranted.
Conversion of Flow-restrictive Ahmed Glaucoma Valve to a Nonrestrictive Drainage Implant by Slicing the Valve Leaflets: An In Vitro Study.
It was possible to convert the flow-restrictive AGV into a non-flow-restrictive device by destroying the functionality of the valve leaflets. The pressure of the AGVs was similar to AADI after destroying its valve functionality.
Re: Yu et al.: Risk of visual field progression in glaucoma patients with progressive retinal nerve fiber layer thinning (Ophthalmology. 2016;123:1201-1210).
Aqueous misdirection syndrome: clinical outcomes and risk factors for treatment failure.
Pseudophakic eyes were more refractory and predicted the need for multiple interventions.
A Simplified (Screening) Approach to Check the Calibration Status of the Goldmann Applanation Tonometer.
The screening criteria of calibration error within ±1 mm Hg at the 0 mm Hg testing level seem to be clinically useful to detect GAT with an acceptable calibration error as per the APGS guideline.
Outcomes of Primary Trabeculectomy With Mitomycin-C in Glaucoma Secondary to Iridocorneal Endothelial Syndrome.
Primary trabeculectomy with MMC offers moderate surgical success in patients with ICE syndrome. Maintaining long-term IOP control and corneal clarity in these eyes is a big challenge.
Comparison of Cataract Surgery Alone Versus Cataract Surgery Combined With Trabeculectomy in the Management of Phacomorphic Glaucoma.
In our cohort of phacomorphic glaucoma presenting within 4 weeks of onset, cataract surgery and combined surgery resulted in similar IOP control at 6 months.
Diagnostic Abilities of Variable and Enhanced Corneal Compensation Algorithms of GDx in Different Severities of Glaucoma.
In scans satisfying the manufacturer-recommended quality parameters, which were significantly greater with ECC than VCC algorithm, diagnostic abilities of GDx ECC and VCC in glaucoma were similar.
Comparing the Structure-Function Relationship at the Macula With Standard Automated Perimetry and Microperimetry.
Visual sensitivity measurements of both SAP and MP demonstrated a similar relationship with the GCIPL measurements of SDOCT at the macula in glaucoma.
Reference Standard Test and the Diagnostic Ability of Spectral Domain Optical Coherence Tomography in Glaucoma.
Diagnostic parameters of SDOCT that was significantly affected by reference standard was the specificity, which was greater with optic disc classification as the reference standard.
Structure-Function Relationship in Glaucoma Using Ganglion Cell-Inner Plexiform Layer Thickness Measurements.
Significant structure-function associations were found between GCIPL thickness measurements at the macula and the functional loss measured on 10-2 SAP in glaucoma.
The ISNT rule in glaucoma: revisiting with spectral domain optical coherence tomography.
Neuroretinal rim rules, as determined by SDOCT, do not allow robust differentiation of glaucomatous from non-glaucomatous discs.
Re: Charlson et al.: Nocturnal systemic hypotension increases the risk of glaucoma progression (Ophthalmology 2014;121:2004-12).
Atypical birefringence pattern and the diagnostic ability of scanning laser polarimetry with enhanced corneal compensation in glaucoma.
Diagnostic performances of TSNIT and inferior average RNFL parameters with ECC protocol of SLP were significantly influenced by TSS even when the TSS values were within the acceptable limits.
Comparing spectral-domain optical coherence tomography and standard automated perimetry to diagnose glaucomatous optic neuropathy.
Most of the RNFL and GCC parameters of SDOCT had better sensitivities and negative LRs to diagnose GON compared with SAP.
Role of visual field reliability indices in ruling out glaucoma.
This study suggests that FN response rates have an effect on the ability of automated VF assessments to rule out glaucoma.