Invest Ophthalmol Vis Sci
Invest Ophthalmol Vis SciJuly 2016Journal Article

Test-Retest Variability of Fundus-Tracked Perimetry at the Peripapillary Region in Open Angle Glaucoma.

Visual FieldDiagnosis & Screening

Summary

On a pointwise basis, the test-retest variability of visual sensitivity in glaucoma is not just related to its measured level, but also its local gradient when using fundus-tracked perimetry.

Abstract

PURPOSE

To examine the association between the measured level and local gradient of visual sensitivity on the magnitude of test-retest variability of its measurements at the peripapillary region using fundus-tracked perimetry in eyes with glaucoma.

METHODS

A total of 30 participants with open angle glaucoma underwent three examinations in one eye on fundus-tracked perimetry using a stimulus pattern that sampled the peripapillary region densely. Factors associated with the magnitude of test-retest variability at each location were examined.

RESULTS

There was no significant change in average pointwise sensitivity (PWS) between tests 1 and 2 (P = 0.855), but a significant reduction between tests 2 and 3 (P 4 dB/location).

CONCLUSIONS

On a pointwise basis, the test-retest variability of visual sensitivity in glaucoma is not just related to its measured level, but also its local gradient when using fundus-tracked perimetry. Locations with low sensitivity do not necessarily demonstrate very high test-retest variability, depending on the local uniformity of visual field damage.