PURPOSE
To compare safety, tolerability and intraocular pressure (IOP)-lowering efficacy of pattern scanning laser trabeculoplasty (PSLT) with selective laser trabeculoplasty (SLT) in fellow eyes of untreated patients with glaucoma.
DESIGN
Randomized controlled trial.
PARTICIPANTS
Twenty-nine patients (58 eyes) with primary and secondary open angle glaucoma (OAG) were randomized to undergo PSLT or SLT in each eye.
METHODS
Pattern scanning laser trabeculoplasty was performed using the Pascal laser (Pascal Streamline 577; Topcon Inc., Tokyo, Japan). Patients' comfort level to treatment was assessed using a visual analogue scale (VAS). Follow-up visits were at week 1, month 1, 3 and 6. Success was defined as IOP reduction ≥20%.
MAIN OUTCOME MEASURES
Safety, tolerability and IOP reduction.
RESULTS
The mean age of patients was 54.1 ± 15.5 years. Baseline IOP was similar between both groups (PSLT, 17.3 ± 4.0 mmHg; SLT, 16.8 ± 3.6 mmHg, p > 0.05). In the PSLT group, the mean IOP at 1, 3 and 6 months was 14.2 ± 3.5, 13.9 ± 2.6 and 14.0 ± 2.7 mmHg, respectively. In the SLT group, the mean IOP at 1, 3 and 6 months was 14.4 ± 4.1, 13.7 ± 3.2 and 13.7 ± 3.1 mmHg, respectively. The IOP reduction in the PSLT group was greater than the SLT group at 1 month (p < 0.01) and 3 months (p < 0.01). VAS score was better in PSLT eyes: 23.9 ± 20.5 (range, 0-82) than in SLT eyes: 50.4 ± 25.3 (range, 0-98) (p < 0.001). No serious adverse events were recorded.
CONCLUSIONS
Both laser modalities had similar safety and efficacy profiles while PSLT was better tolerated by patients.
Keywords
More by Kaweh Mansouri
View full profile →Prospective Evaluation of Standalone XEN Gel Implant and Combined Phacoemulsification-XEN Gel Implant Surgery: 1-Year Results.
Repeatability of vessel density measurements of optical coherence tomography angiography in normal and glaucoma eyes.
Reproducibility of Optical Coherence Tomography Angiography Macular and Optic Nerve Head Vascular Density in Glaucoma and Healthy Eyes.
Top Research in IOP & Medical Therapy
Browse all →The Complications of Myopia: A Review and Meta-Analysis.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Treatment Outcomes in the Primary Tube Versus Trabeculectomy Study after 1 Year of Follow-up.
Discussion
Comments and discussion will appear here in a future update.