A Prospective Longitudinal Study to Investigate Corneal Hysteresis as a Risk Factor for Predicting Development of Glaucoma.
Carolina N Susanna, Alberto Diniz-Filho, Fábio B Daga, Bianca N Susanna, Feilin Zhu, Nara G Ogata, Felipe A Medeiros
Summary
Baseline lower CH measurements were significantly associated with increased risk of developing glaucomatous visual field defects over time.
Abstract
PURPOSE
To investigate the role of corneal hysteresis (CH) as a risk factor for development of glaucoma.
DESIGN
Prospective observational cohort study.
METHODS
Two hundred and eighty-seven eyes of 199 patients suspected of having glaucoma were followed for an average of 3.9 ± 1.8 years. All eyes had normal visual fields at baseline. Development of glaucoma was defined as occurrence of 3 consecutive abnormal standard automated perimetry tests during follow-up, defined as pattern standard deviation (PSD) < 5%, and/or Glaucoma Hemifield Test outside normal limits. Measurements of CH were acquired at baseline using the Ocular Response Analyzer (ORA). Univariable and multivariable Cox regression models were used to investigate baseline factors associated with development of visual field loss over time.
RESULTS
Fifty-four (19%) eyes developed repeatable visual field defects during follow-up. Measurements of CH at baseline were significantly lower in patients who developed glaucoma vs those who did not (9.5 ± 1.5 mm Hg vs 10.2 ± 2.0 mm Hg; P = .012). Each 1-mm Hg lower CH was associated with an increase of 21% in the risk of developing glaucoma during follow-up (95% confidence interval [CI]: 1.04-1.41; P = .013). In a multivariable model adjusting for age, intraocular pressure, central corneal thickness, PSD, and treatment, CH was still predictive of development of glaucoma (hazard ratio = 1.20; 95%
CI
1.01-1.42; P = .040).
CONCLUSION
Baseline lower CH measurements were significantly associated with increased risk of developing glaucomatous visual field defects over time. The prospective longitudinal design of this study supports a role of CH as a risk factor for developing glaucoma.
More by Carolina N Susanna
View full profile →Corneal Biomechanics and Visual Field Progression in Eyes with Seemingly Well-Controlled Intraocular Pressure.
Reply.
Association between Rates of Visual Field Progression and Intraocular Pressure Measurements Obtained by Different Tonometers.
Top Research in Visual Field
Browse all →Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Improving our understanding, and detection, of glaucomatous damage: An approach based upon optical coherence tomography (OCT).
Discussion
Comments and discussion will appear here in a future update.