Diagnostic Ability and Structure-function Relationship of Peripapillary Optical Microangiography Measurements in Glaucoma.
Harsha L Rao, Srilakshmi Dasari, Mohammed Riyazuddin, Narendra K Puttaiah, Zia S Pradhan, Robert N Weinreb, Kaweh Mansouri, Carroll A B Webers
Summary
The inferior sector OMAG measurements had the best diagnostic ability in glaucoma and the strongest association with RNFL and the visual sensitivity measurements.
Abstract
PURPOSE
The aim of this study was to evaluate the diagnostic abilities of peripapillary optical microangiography (OMAG) measurements in eyes with primary open-angle glaucoma (POAG) and to evaluate the relationship of these measurements with retinal nerve fiber layer (RNFL) thickness and visual sensitivities in different peripapillary sectors.
METHODS
In a cross-sectional study, 97 eyes of 57 control subjects and 101 eyes of 66 POAG patients underwent OMAG and RNFL imaging with optical coherence tomography. POAG was diagnosed on the basis of the masked evaluation of optic disc stereo photographs. Area under receiver operating characteristic curves and sensitivities at 90% specificity of the OMAG and RNFL thickness measurements in different peripapillary sectors were evaluated. Association between OMAG, RNFL thickness, and visual sensitivity measurements were evaluated using fractional polynomial regression models.
RESULTS
All OMAG and RNFL measurements were significantly less in the POAG compared with the control eyes. Diagnostic abilities of the best OMAG measurement (inferior sector vessel length density, area under receiver operating characteristic curves: 0.84, sensitivity at 90%, specificity: 65%) were significantly less (P<0.05) than that of the best RNFL measurement (inferior sector RNFL thickness, 0.94 and 81%). Inferior sector vessel length density showed the strongest association with inferior sector RNFL thickness (R=0.66, P<0.001) and the superior sector visual sensitivity loss (R=0.21, P=0.006).
CONCLUSIONS
The inferior sector OMAG measurements had the best diagnostic ability in glaucoma and the strongest association with RNFL and the visual sensitivity measurements. Diagnostic ability of OMAG measurements, however, were significantly less than the RNFL thickness measurements.
More by Harsha L Rao
View full profile →Regional Comparisons of Optical Coherence Tomography Angiography Vessel Density in Primary Open-Angle Glaucoma.
Prospective Evaluation of Standalone XEN Gel Implant and Combined Phacoemulsification-XEN Gel Implant Surgery: 1-Year Results.
Diagnostic ability of peripapillary vessel density measurements of optical coherence tomography angiography in primary open-angle and angle-closure glaucoma.
Top Research in Optic Nerve & Disc
Browse all →Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.