Glaucoma Journal Club

In this database

19

2016 – 2025

DB Citations

822

across indexed articles

h-index

Not available

Total Citations

Not available

19 articles in Glaucoma Journal Club

Regional Comparisons of Optical Coherence Tomography Angiography Vessel Density in Primary Open-Angle Glaucoma.

Diagnostic ability of the vessel density parameters of OCTA was only moderate.

American journal of ophthalmology2016 Nov256 citations
oct-imagingiop-medical-therapy

Repeatability of vessel density measurements of optical coherence tomography angiography in normal and glaucoma eyes.

Repeatability estimates of OCTA measured peripapillary and macular vessel densities were similar in normal eyes and eyes with glaucoma.

The British journal of ophthalmology2018 Mar133 citations
oct-imagingoptic-nerve

Vessel Density and Structural Measurements of Optical Coherence Tomography in Primary Angle Closure and Primary Angle Closure Glaucoma.

These results suggest that structural changes in PACG occur earlier than the reduction in retinal vessel densities.

American journal of ophthalmology2017 May92 citations
optic-nerveoct-imaging

Relationship of Optic Nerve Structure and Function to Peripapillary Vessel Density Measurements of Optical Coherence Tomography Angiography in Glaucoma.

The inferotemporal peripapillary vessel density showed the strongest association with the corresponding retinal nerve fiber layer thickness and visual sensitivity loss in the global and sectoral regions studied.

Journal of glaucoma2017 Jun64 citations
optic-nervevisual-field

A 3D Deep Learning System for Detecting Referable Glaucoma Using Full OCT Macular Cube Scans.

A 3D deep learning algorithm trained on macular OCT volumes without retinal disease to detect referable glaucoma performs better with retinal segmentation preprocessing and performs reasonably well across all levels of myopia.

Translational vision science & technology2020 Feb 1850 citations
oct-imagingiop-medical-therapy

Deep Learning for Glaucoma Detection and Identification of Novel Diagnostic Areas in Diverse Real-World Datasets.

A 3D convolutional neural network (CNN) trained on SD-OCT ONH cubes can distinguish glaucoma from normal cases in diverse datasets obtained from four different countries.

Translational vision science & technology2022 May 237 citations
optic-nerveoct-imaging

Choroidal Microvascular Dropout in Primary Open-angle Glaucoma Eyes With Disc Hemorrhage.

Prevalence of CMvD was significantly greater in POAG eyes with DH compared with POAG eyes without DH. CMvD in POAG eyes was also significantly associated with central VF defects and greater severity of glaucomatous damage.

Journal of glaucoma2019 Mar32 citations
visual-fieldoct-imaging

Choroidal Microvascular Dropout in Primary Angle Closure Glaucoma.

Prevalence of CMvD was significantly lower in PACG compared to POAG. As in POAG, CMvD in PACG was associated with advanced VF damage and with IPFS on VF.

American journal of ophthalmology2019 Mar29 citations
visual-fieldoct-imaging

Diagnostic Abilities of the Optical Microangiography Parameters of the 3×3 mm and 6×6 mm Macular Scans in Glaucoma.

The outer sector measurements of the 6×6 mm macular OMAG scans seem to be better than the inner sector measurements in diagnosing glaucoma.

Journal of glaucoma2018 Jun25 citations
glaucoma-diagnosisoptic-nerve

Optical Coherence Tomography Angiography Vessel Density Measurements in Eyes With Primary Open-Angle Glaucoma and Disc Hemorrhage.

OCT angiography measured vessel densities and their diagnostic abilities in POAG eyes with and without DH were similar. This suggests that the cause of DH in POAG is unlikely to be vascular abnormality.

Journal of glaucoma2017 Oct23 citations
optic-nerveoct-imaging

A Comparison of the Visual Field Parameters of SITA Faster and SITA Standard Strategies in Glaucoma.

VF parameters with SFR showed good agreement with that of SS strategy. This, combined with low test-retest variability, suggests that SFR can be considered for diagnosis and monitoring of glaucoma.

Journal of glaucoma2020 Sep20 citations
visual-fieldglaucoma-diagnosis

Diagnostic Ability and Structure-function Relationship of Peripapillary Optical Microangiography Measurements in Glaucoma.

The inferior sector OMAG measurements had the best diagnostic ability in glaucoma and the strongest association with RNFL and the visual sensitivity measurements.

Journal of glaucoma2018 Mar17 citations
optic-nerveglaucoma-diagnosis

Comparing the Performance of Compass Perimetry With Humphrey Field Analyzer in Eyes With Glaucoma.

The numbers of unreliable tests were higher with Compass compared with HFA.

Journal of glaucoma2017 Mar16 citations
visual-fieldglaucoma-diagnosis

Relationship of Macular Thickness and Function to Optical Microangiography Measurements in Glaucoma.

The strongest associations between OMAG, GCIPL thickness, and visual sensitivity measurements were found in the inferior macular sector.

Journal of glaucoma2018 Mar9 citations
visual-fieldoct-imaging

Predicting the Magnitude of Functional and Structural Damage in Glaucoma From Monocular Pupillary Light Responses Using Automated Pupillography.

Glaucomatous damage as estimated by MD, RNFL, and GCC thickness measurements were best predicted by the latency parameters (Loc and Lmaxc) of pupillography.

Journal of glaucoma2017 May7 citations
optic-nervevisual-field

Optical Microangiography and Progressive Retinal Nerve Fiber Layer Loss in Primary Open Angle Glaucoma.

Lower baseline peripapillary PD and VD measured using OMAG were significantly associated with a faster rate of RNFL loss in POAG.

American journal of ophthalmology2022 Jan5 citations
optic-nerveglaucoma-progression

Predicting the intereye asymmetry in functional and structural damage in glaucoma using automated pupillography.

Intereye asymmetry in MD, RNFL and GCC thickness measurements was best predicted by the intereye difference in Ac per cent on automated pupillography.

Acta ophthalmologica2017 Nov5 citations
oct-imagingvisual-field

Optical Microangiography and Progressive Ganglion Cell-Inner Plexiform Layer Loss in Primary Open-Angle Glaucoma.

Lower baseline peripapillary OMAG measurements were significantly associated with a faster rate of GCIPL loss in patients with mild to moderate POAG.

American journal of ophthalmology2022 Jun2 citations
optic-nerveiop-medical-therapy

Optical Microangiography and Progressive Retinal Nerve Fiber Layer Loss in Primary Angle Closure Glaucoma.

Younger patient age and greater peak IOP during follow-up were significantly associated with a faster rate of RNFL loss in PACG patients with mild to moderate severity of functional damage.

Journal of glaucoma2025 Mar 1
oct-imagingglaucoma-progression