Optical Microangiography and Progressive Ganglion Cell-Inner Plexiform Layer Loss in Primary Open-Angle Glaucoma.
Harsha L Rao, Srilakshmi Dasari, Narendra K Puttaiah, Zia S Pradhan, Sasan Moghimi, Kaweh Mansouri, Carroll A B Webers, Robert N Weinreb
Summary
Lower baseline peripapillary OMAG measurements were significantly associated with a faster rate of GCIPL loss in patients with mild to moderate POAG.
Abstract
PURPOSE
To evaluate the association between optical microangiography (OMAG) measurements and progressive ganglion cell-inner plexiform layer (GCIPL) loss in patients with primary open-angle glaucoma (POAG).
DESIGN
Prospective case series.
METHODS
Sixty-three eyes of 38 patients with POAG were studied for ≥2 years and with ≥ 3 optical coherence tomography examinations. Only those hemifields with mild to moderate functional damage at baseline (106 hemifields) were included in the analysis. OMAG imaging was performed at the baseline visit. The effects of clinical parameters (age, gender, central corneal thickness, presence of disc hemorrhage, and mean and fluctuation of intraocular pressure), baseline mean deviation, retinal nerve fiber layer, and GCIPL thickness and baseline OMAG measurements (peripapillary and macular perfusion density [PD] and vessel density [VD]) on the rate of change of GCIPL thickness were evaluated using linear mixed models.
RESULTS
Average (± standard deviation) mean deviation, quadrant retinal nerve fiber layer, and sector GCIPL thickness of the analyzed hemifields respectively at baseline were -5.2 ± 2.8 dB, 94.5 ± 20.0 µm, and 72.4 ± 8.7 µm, respectively. Peripapillary PD and VD in the quadrant were 43.1% ± 7.0% and 17.0 ± 2.6 mm/mm, respectively. Macular PD and VD in the quadrant were 37.2% ± 6.9% and 15.1 ± 2.6 mm/mm, respectively. Rate of sector GCIPL change was -0.97 ± 0.15 µm per year. Multivariate mixed models showed that lower peripapillary PD (coefficient 0.04, P = .01) and VD (coefficient 0.09, P = .05) were significantly associated with a faster rate of GCIPL loss.
CONCLUSIONS
Lower baseline peripapillary OMAG measurements were significantly associated with a faster rate of GCIPL loss in patients with mild to moderate POAG.
More by Harsha L Rao
View full profile →Regional Comparisons of Optical Coherence Tomography Angiography Vessel Density in Primary Open-Angle Glaucoma.
Prospective Evaluation of Standalone XEN Gel Implant and Combined Phacoemulsification-XEN Gel Implant Surgery: 1-Year Results.
Diagnostic ability of peripapillary vessel density measurements of optical coherence tomography angiography in primary open-angle and angle-closure glaucoma.
Top Research in Optic Nerve & Disc
Browse all →Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Discussion
Comments and discussion will appear here in a future update.