Histopathologic Examination of Trabecular Meshwork Changes After Trabecular Bypass Stent Implantation.
Young Cara E Capitena, David A Ammar, Leonard K Seibold, Mina B Pantcheva, Jeffrey R SooHoo, Malik Y Kahook
Summary
These findings indicate that inflammatory and fibrotic changes are present surrounding the device with clear differences noted when compared with both healthy and glaucomatous controls.
Abstract
PURPOSE
The purpose of this article was to evaluate how human trabecular meshwork (TM) is influenced by the chronic presence of trabecular bypass implants.
METHODS
Human TM samples were obtained intraoperatively from 3 patients who had previously undergone implantation of a trabecular micro-bypass stent. Trabecular strips were obtained with a goniotomy blade from areas directly adjacent to the stent after stent removal. Tissue samples were preserved, processed, cut, and stained according to standardized laboratory protocol. Harvested samples were compared with human cadaveric TM from an eye without ocular disease as well as TM obtained from a glaucomatous eye without prior stent placement.
RESULTS
In all samples, a significant increase in the amount of fibrous material compared with cellular material was noted when compared with controls. In a single strip, a basement membrane-like structure was noted, which correlated with a semiopaque membrane noted intraoperatively overlying the stent and adjacent TM. Further, TM cells were absent from areas adjacent to the stent implantation site with related collapse of collagen beams.
CONCLUSIONS
These findings indicate that inflammatory and fibrotic changes are present surrounding the device with clear differences noted when compared with both healthy and glaucomatous controls. These changes suggest a possible etiology for device failure over time. Further studies are necessary to tease out differences in TM tissue reaction to various implant materials as well as to make comparisons to procedures that excise TM.
More by Young Cara E Capitena
View full profile →Efficacy of Goniotomy With Kahook Dual Blade in Patients With Uveitis-associated Ocular Hypertension.
Outcomes of Kahook Dual Blade Goniotomy for Uveitis Associated Open Angle Glaucoma or Ocular Hypertension.
A Comparison of Clinical Outcomes After XEN Gel Stent and EX-PRESS Glaucoma Drainage Device Implantation.
Top Research in Glaucoma Surgery
Browse all →Treatment Outcomes in the Primary Tube Versus Trabeculectomy Study after 1 Year of Follow-up.
Efficacy, Safety, and Risk Factors for Failure of Standalone Ab Interno Gelatin Microstent Implantation versus Standalone Trabeculectomy.
Prospective, Randomized, Controlled Pivotal Trial of an Ab Interno Implanted Trabecular Micro-Bypass in Primary Open-Angle Glaucoma and Cataract: Two-Year Results.
Discussion
Comments and discussion will appear here in a future update.