The Effect of Therapeutic IOP-lowering Interventions on the 24-hour Ocular Dimensional Profile Recorded With a Sensing Contact Lens.
Carlo A Cutolo, Moraes Carlos G De, Jeffrey M Liebmann, Kaweh Mansouri, Carlo E Traverso, Robert Ritch
Summary
Incisional glaucoma surgery had a more pronounced effect on GAT and CLS parameters than laser and drugs.
Abstract
UNLABELLED
PRéCIS:: The 24-hour ocular dimensional profile recorded by a contact lens sensor was affected by intraocular pressure lowering interventions. Among different treatments, incisional surgery had the most significant effect.
PURPOSE
We investigated the effect of different intraocular pressure (IOP)-lowering interventions on contact lens sensor (CLS) parameters and their relationship with Goldmann applanation tonometry (GAT)-measured IOP reduction.
METHODS
Data from reliable CLS recordings performed before and after IOP-lowering interventions were analyzed. Three interventions were evaluated: topical medications, laser trabeculoplasty, and incisional surgery. A set of 115 different CLS parameters were derived from 24-hour curves. We compared before versus after values for each parameter. In addition, linear regression was performed using the percentage change of each CLS parameter as the outcome variable and the type of IOP-lowering procedure as the predictor after adjusting age and race. Finally, we investigated the relationship between changes in CLS parameters and GAT IOP with the Spearman rank correlation coefficient.
RESULTS
A total of 182 eyes of 182 patients were included in the analyses: 60 (33%) topical medications, 69 (38%) laser, and 53 (29%) surgery. The mean GAT IOP change was 3.6±6.5 mm Hg (Plaser=drug). Linear regression showed that, for 20 CLS parameters, surgery was the most predictive of greatest percentage change in CLS signals. In all, 11 (9.5%) of the CLS parameters were significantly correlated with GAT changes.
CONCLUSIONS
Incisional glaucoma surgery had a more pronounced effect on GAT and CLS parameters than laser and drugs. The CLS can detect changes in patterns resulting from IOP-lowering interventions beyond daytime GAT IOP. This device could potentially be used to assess treatment efficacy in glaucoma.
More by Carlo A Cutolo
View full profile →XEN Implant Fracture During Needling Procedure.
What Do We Really Know about the Effectiveness of Glaucoma Interventions?: An Overview of Systematic Reviews.
Risk Factors for Failure in Glaucoma Patients Undergoing Microshunt Implantation.
Top Research in IOP & Medical Therapy
Browse all →The Complications of Myopia: A Review and Meta-Analysis.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Treatment Outcomes in the Primary Tube Versus Trabeculectomy Study after 1 Year of Follow-up.
Discussion
Comments and discussion will appear here in a future update.