A Novel Surgical Technique for Ahmed Glaucoma Valve Implantation Without Plate Sutures.
Carina T Sanvicente, Marlene R Moster, Daniel Lee, Alicia Menezes, Aria Ghahramani, Qiang Zhang, Rose Hamershock, Jonathan S Myers
Summary
The comparison of short and mid-term outcomes of patients undergoing AGV implantation using both techniques showed similar outcomes and success rates.
Abstract
UNLABELLED
PRéCIS:: A modification to the surgical technique of Ahmed glaucoma valve (AGV) implantation without plate sutures or surgical glue products has a similar safety and efficacy profile than the standard procedure, in the short and mid-term follow-up.
PURPOSE
The purpose of this study was to assess the safety and efficacy of a modified AGV implantation technique without plate sutures.
METHODS
A retrospective case-control study including patients seen in the Glaucoma service of an academic institution. Patients that underwent a modified AGV implantation without plate sutures were included as cases and patients that underwent standard AGV implantation, as controls. Success was defined as intraocular pressure (IOP) reduction >20%, IOP >5 and <21 without the need for additional surgical intervention, and maintenance of light perception.
RESULTS
A total of 170 eyes were included. Mean (range) follow-up was 11.2±7.39 (3 to 24) months. There was no statistically significant difference in visual acuity and IOP between the groups during the postoperative period. In a univariate analysis, there was a larger decrease in IOP for the no plate suture group at the 6 months (-15.6±11.6 vs. -11.5±10.5, P=0.04) and 1 year (-16.4±10.4 vs. -11.1±10.4, P=0.02) visits. There was also a larger decrease in number of medications in the no plate suture group in the 3 months (-1.65±1.5 vs. -1.13±1.22, P=0.02), 6 months (-1.55±1.44 vs. -0.98±1.3, P=0.01) and 1 year (-1.70±1.5 vs. -1.04±1.2, P=0.04) visits. However, those differences were not confirmed by a multivariable model after adjusting for glaucoma type and number of previous glaucoma surgeries. No differences in the trajectory of the survival curves were noted between groups (P=0.36).
CONCLUSION
The comparison of short and mid-term outcomes of patients undergoing AGV implantation using both techniques showed similar outcomes and success rates.
More by Carina T Sanvicente
View full profile →Association of Primary Open-Angle Glaucoma with Diabetic Retinopathy among Patients with Type 1 and Type 2 Diabetes: A Large Global Database Study.
Vision-related Performance and Quality of Life of Patients With Rapid Glaucoma Progression.
Outcomes of trabecular microbypass surgery: Comparison of resident trainees and attending surgeons.
Top Research in IOP & Medical Therapy
Browse all →The Complications of Myopia: A Review and Meta-Analysis.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Treatment Outcomes in the Primary Tube Versus Trabeculectomy Study after 1 Year of Follow-up.
Discussion