Combined CS and microstent placement for mild to moderate POAG is safe, more effective in lowering IOP with fewer medications, and less likely to result in further incisional glaucoma filtration surgery than CS alone at…
Abstract
PURPOSE
To report 3-year outcomes of the HORIZON study comparing cataract surgery (CS) with Hydrus Microstent (Ivantis, Inc) implantation versus CS alone.
DESIGN
Multicenter randomized clinical trial.
PARTICIPANTS
Five hundred fifty-six eyes from 556 patients with cataract and primary open-angle glaucoma (POAG) treated with 1 or more glaucoma medication, washed out diurnal intraocular pressure (IOP) of 22 to 34 mmHg, and no prior incisional glaucoma surgery.
METHODS
After phacoemulsification, eyes were randomized 2:1 to receive a Hydrus Microstent or no stent. Follow-up included comprehensive eye examinations through 3 years.
MAIN OUTCOME MEASURES
Outcome measures included IOP, medical therapy, reoperation rates, visual acuity, adverse events, and changes in corneal endothelial cell counts.
RESULTS
Three hundred sixty-nine eyes were randomized to microstent treatment and 187 to CS only. Preoperative IOP, medication use, washed-out diurnal IOP, and glaucoma severity did not differ between the two treatment groups. At 3 years, IOP was 16.7 ± 3.1 mmHg in the microstent group and 17.0 ± 3.4 mmHg in the CS group (P = 0.85). The number of glaucoma medications was 0.4 ± 0.8 in the microstent group and 0.8 ± 1.0 in the CS group (P < 0.001), and 73% of microstent group eyes were medication free compared with 48% in the CS group (P < 0.001). The microstent group included a higher proportion of eyes with IOP of 18 mmHg or less without medications compared with the CS group (56.2% vs. 34.6%; P < 0.001), as well as IOP reduction of at least 20%, 30%, or 40% compared with CS alone. The cumulative probability of incisional glaucoma surgery was lower in the microstent group (0.6% vs. 3.9%; hazard ratio, 0.156; 95% confidence interval, 0.031-0.773; P = 0.020). No difference was found in postoperative corneal endothelial cell loss between groups. No procedure- or device-related serious adverse events resulting in vision loss occurred in either group.
CONCLUSIONS
Combined CS and microstent placement for mild to moderate POAG is safe, more effective in lowering IOP with fewer medications, and less likely to result in further incisional glaucoma filtration surgery than CS alone at 3 years.
Keywords
More by Iqbal Ike K Ahmed
View full profile →Efficacy, Safety, and Risk Factors for Failure of Standalone Ab Interno Gelatin Microstent Implantation versus Standalone Trabeculectomy.
A Schlemm Canal Microstent for Intraocular Pressure Reduction in Primary Open-Angle Glaucoma and Cataract: The HORIZON Study.
A Prospective Randomized Trial Comparing Hydrus and iStent Microinvasive Glaucoma Surgery Implants for Standalone Treatment of Open-Angle Glaucoma: The COMPARE Study.
Top Research in IOP & Medical Therapy
Browse all →The Complications of Myopia: A Review and Meta-Analysis.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Treatment Outcomes in the Primary Tube Versus Trabeculectomy Study after 1 Year of Follow-up.
In the Knowledge Library
Discussion
Comments and discussion will appear here in a future update.