Long- and Short-Term Variability of Perimetry in Glaucoma.
Summary
Long-term and short-term variability both increase with damage for perimetric stimuli smaller than Ricco's area. Above 28 dB, long-term variability constitutes a negligible proportion of test-retest variability.
Abstract
PURPOSE
Test-retest variability in perimetry consists of short-term and long-term components, both of which impede assessment of progression. By minimizing and quantifying the algorithm-dependent short-term variability, we can quantify the algorithm-independent long-term variability that reflects true fluctuations in sensitivity between visits. We do this at locations with sensitivity both 28 dB (when partial summation occurs).
METHODS
Frequency-of-seeing curves were measured at four locations of 35 participants with glaucoma. The standard deviation of cumulative Gaussian fits to those curves was modeled for a given sensitivity and used to simulate the expected short-term variability of a 30-presentation algorithm. A separate group of 137 participants was tested twice with that algorithm, 6 months apart. Long-term variance at different sensitivities was calculated as the LOESS fit of observed test-retest variance minus the LOESS fit of simulated short-term variance.
RESULTS
Below 28 dB, short-term variability increased approximately linearly with increasing loss. Long-term variability also increased with damage below this point, attaining a maximum standard deviation of 2.4 dB at sensitivity 21 dB, before decreasing due to the floor effect of the algorithm. Above 30 dB, the observed test-retest variance was slightly smaller than the simulated short-term variance.
CONCLUSIONS
Long-term and short-term variability both increase with damage for perimetric stimuli smaller than Ricco's area. Above 28 dB, long-term variability constitutes a negligible proportion of test-retest variability.
TRANSLATIONAL RELEVANCE
Fluctuations in true sensitivity increase in glaucoma, even after accounting for increased short-term variability. This long-term variability cannot be reduced by altering testing algorithms alone.
More by Stuart K Gardiner
View full profile →Automated Segmentation Errors When Using Optical Coherence Tomography to Measure Retinal Nerve Fiber Layer Thickness in Glaucoma.
The connective tissue phenotype of glaucomatous cupping in the monkey eye - Clinical and research implications.
Factors Influencing Central Lamina Cribrosa Depth: A Multicenter Study.
Top Research in Visual Field
Browse all →Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Improving our understanding, and detection, of glaucomatous damage: An approach based upon optical coherence tomography (OCT).
In the Knowledge Library
Discussion
Comments and discussion will appear here in a future update.