Two-Year Performance and Safety Results of the MINIject Supraciliary Implant in Patients With Primary Open-Angle Glaucoma: Meta-Analysis of the STAR-I, II, III Trials.
H Burkhard Dick, Marc J Mackert, Iqbal Ike K Ahmed, Philippe Denis, Christoph Hirneiß, Brian E Flowers, I Paul Singh, Kaweh Mansouri, Antonio M Fea
Summary
This meta-analysis demonstrates the favorable safety and efficacy profile of a supraciliary device implanted in a stand-alone, ab-interno procedure in patients with mild-to-moderate POAG.
Abstract
PURPOSE
To evaluate the performance and safety of minimally invasive glaucoma surgery with a supraciliary drainage device (MINIject; iSTAR Medical, Wavre, Belgium) in primary open-angle glaucoma (POAG) as a stand-alone procedure.
DESIGN
Meta-analysis.
METHODS
At 11 sites in Colombia, France, Germany, India, Panama, and Spain, 82 patients were treated in 3 prospective, multicenter, interventional, nonrandomized trials (STAR-I, II, III). Data were pooled in a meta-analysis of up to 2 years of follow-up postimplantation. The main outcome measures were mean relative and absolute reduction in diurnal intraocular pressure (IOP) compared to baseline. Secondary outcomes included patients with IOP ≤18 mmHg, patients with IOP reduction ≥20%, number of IOP-lowering medications, adverse events, and endothelial cell density loss.
RESULTS
At the 2-year follow-up (n = 66), mean IOP was reduced from 23.8 ± 3.3 mmHg at baseline to 14.4 ± 4.5 mmHg (-39.3%; P 30%.
CONCLUSIONS
This meta-analysis demonstrates the favorable safety and efficacy profile of a supraciliary device implanted in a stand-alone, ab-interno procedure in patients with mild-to-moderate POAG. The data demonstrate that MINIject is a safe and effective, bleb-free treatment option for patients requiring low target IOP up to 2 years.
More by H Burkhard Dick
View full profile →Telemetric Measurement of Intraocular Pressure via an Implantable Pressure Sensor-12-Month Results from the ARGOS-02 Trial.
Future Intraocular Lens Technologies.
EYEMATE-SC Trial: Twelve-Month Safety, Performance, and Accuracy of a Suprachoroidal Sensor for Telemetric Measurement of Intraocular Pressure.
Top Research in IOP & Medical Therapy
Browse all →The Complications of Myopia: A Review and Meta-Analysis.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Treatment Outcomes in the Primary Tube Versus Trabeculectomy Study after 1 Year of Follow-up.
In the Knowledge Library
Discussion
Comments and discussion will appear here in a future update.