H. Burkhard Dick
Goethe University Frankfurt · University Hospitals of the Ruhr-University of Bochum · Augenklinik Heidelberg
In this database
11
2016 – 2025
DB Citations
134
across indexed articles
h-index
56
OpenAlex (all works)
Total Citations
11,517
OpenAlex (all works)
11 articles in Glaucoma Journal Club
Telemetric Measurement of Intraocular Pressure via an Implantable Pressure Sensor-12-Month Results from the ARGOS-02 Trial.
The EYEMATE-IO sensor was safely implanted in 22 patients and performed reliably until the end of follow-up. This device allows for continual and long-term measurements of IOP.
Future Intraocular Lens Technologies.
The last generation of this device (Eyemate; Implandata Opthalmics Products GmbH) is implanted during small-incision cataract surgery; the latest development is an even smaller sensor that will be inserted suprachoroidally before, in the near future, such a device will be part of a capsular ring.
EYEMATE-SC Trial: Twelve-Month Safety, Performance, and Accuracy of a Suprachoroidal Sensor for Telemetric Measurement of Intraocular Pressure.
The EYEMATE-SC sensor was safe and well tolerated through 12 months. Moreover, it allowed accurate, continuous IOP monitoring. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.
Two-Year Performance and Safety Results of the MINIject Supraciliary Implant in Patients With Primary Open-Angle Glaucoma: Meta-Analysis of the STAR-I, II, III Trials.
This meta-analysis demonstrates the favorable safety and efficacy profile of a supraciliary device implanted in a stand-alone, ab-interno procedure in patients with mild-to-moderate POAG.
Ab externo device for the treatment of glaucoma: direct flow from the anterior chamber to the ocular surface.
Preliminary and early experience have shown success with lowering intraocular pressure immediately postoperatively. In conclusion, the BAM offers a promising minimally invasive surgical procedure.
Long-term Safety and Performance of a Suprachoroidal Pressure Sensor System: Results of the EYEMATE-SC Trial Follow-up Study.
This study demonstrates the long-term safety of the EYEMATE-SC system.
Long-term astigmatism after intraocular pressure sensor implantation and nonpenetrating glaucoma surgery: EYEMATE-SC trial.
Despite its suprachoroidal localization, this study indicated that the miniaturized EYEMATE-SC IOP sensor did not negatively affect long-term astigmatism after combined implantation with NPGS.
Capsular phimosis with intraocular lens tilt and decentration.
Discuss how you would manage this problem, explaining your decisions. How would you be able to avoid the same problem when operating on her fellow eye?
November consultation #9.
Specific Inner Retinal Layer Cell Damage in an Autoimmune Glaucoma Model Is Induced by GDNF With or Without HSP27.
Immunizations led to loss of RGCs and cholinergic amacrine cells and a strong increase in microglial cells.
Early Clinical Results of a Novel Ab Interno Gel Stent for the Surgical Treatment of Open-angle Glaucoma.
The XEN140 gel stent lowers IOP with few complications when implanted for the surgical treatment of open-angle glaucoma.