Relationship Between Intraocular Pressure and the True Rate of Functional and Structural Progression in the United Kingdom Glaucoma Treatment Study.
Summary
VF appeared to deteriorate at a faster rate than structural measurements. However, this could be explained by the floor-effect from nonfunctional tissue. IOP induced a similar acceleration in RoP per mm Hg increase.
Abstract
PURPOSE
To investigate the effect of average intraocular pressure (IOP) on the true rate of glaucoma progression (RoP) in the United Kingdom Glaucoma Treatment Study (UKGTS).
METHODS
UKGTS participants were randomized to placebo or Latanoprost drops and monitored for up to two years with visual field tests (VF, 24-2 SITA standard), IOP measurements, and optic nerve imaging. We included eyes with at least three structural or functional assessments (VF with <15% false-positive errors). Structural tests measured rim area (RA) with Heidelberg retina tomography (HRT) and average peripapillary retinal nerve fiber layer (pRNFL) thickness with optical coherence tomography (OCT). One eye of 436 patients (222 on Latanoprost) was analyzed. A Bayesian hierarchical model estimated the true RoP of VF and structural metrics, and their correlations, using sign-reversed multivariable exponential distribution. RA and pRNFL measurements were converted to a dB scale, matching the VF metric (mean deviation [MD]). The effect of average IOP on the true RoPs was estimated.
RESULTS
True RoP at the mean average IOP (17 mm Hg) was faster (P < 0.001) for VF-MD (-0.59 [-0.73, -0.48] dB/year) than HRT-RA (-0.05 [-0.07, -0.03] dB/year) and OCT-pRNFL (-0.08 [-0.11, -0.06] dB/year). The proportional acceleration of RoP per mm Hg increase was, however, not significantly different (smallest P = 0.15). Accounting for the structural floor-effect largely eliminated the differences in RoPs (smallest P = 0.25).
CONCLUSIONS
VF appeared to deteriorate at a faster rate than structural measurements. However, this could be explained by the floor-effect from nonfunctional tissue. IOP induced a similar acceleration in RoP per mm Hg increase.
More by Giovanni Montesano
View full profile →Visual Field Outcomes from the Multicenter, Randomized Controlled Laser in Glaucoma and Ocular Hypertension Trial (LiGHT).
Efficacy of Repeat Selective Laser Trabeculoplasty in Medication-Naive Open-Angle Glaucoma and Ocular Hypertension during the LiGHT Trial.
A Comparison between the Compass Fundus Perimeter and the Humphrey Field Analyzer.
Top Research in Visual Field
Browse all →Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Improving our understanding, and detection, of glaucomatous damage: An approach based upon optical coherence tomography (OCT).
In the Knowledge Library
Discussion
Comments and discussion will appear here in a future update.