High-Resolution Microperimetry for Detecting Glaucomatous Damage: A Prospective Evaluation of Performance.
Marc G Sarossy, Sandy Rezk, Dongzhe Li, Xavier Hadoux, Maxime Jannaud, Michael A Coote, Ghee Soon Ang, Wijngaarden Peter van, Keith R Martin, Zhichao Wu
Summary
High-resolution microperimetry enabled improved performance for detecting glaucomatous damage compared to SAP, highlighting the potential value of fundus-tracking and higher-resolution sampling for the detection of glaucomatous visual field loss.
Abstract
BACKGROUND
To compare the performance of high-resolution microperimetry testing against standard automated perimetry (SAP) for detecting glaucomatous damage seen on optical coherence tomography (OCT) scans.
METHODS
250 eyes from 200 individuals underwent high-resolution microperimetry testing of a hemifield using a stimulus pattern optimised to sample typical arcuate patterns of visual field loss in glaucoma. SAP was performed using a 24-2 stimulus pattern. The presence of glaucomatous damage in each hemifield was subsequently independently assessed by two graders based on a circumpapillary OCT circle scan, 6×6 mm optic disc-centred OCT volume scan, and 15×15 mm widefield OCT volume scan.
RESULTS
The hemifield-based mean total deviation (MTD) and pointwise sensitivity standard deviation (PSD) for high-resolution microperimetry and SAP were both independently associated with the presence of glaucomatous damage in multivariable logistic regression analyses (p ≤ 0.046). Prediction models developed using these two parameters showed significantly higher performance with high-resolution microperimetry compared to SAP (partial area under the receiver operating characteristic curve [pAUC] = 0.86 and 0.75 respectively; p = 0.007). The performance of microperimetry decreased with decreasing resolution when the MTD and PSD values were derived from every second, third, and sixth test locations (pAUC = 0.85 [p = 0.16], 0.85 [p = 0.044] and 0.84 [p < 0.001] respectively), but they were all significantly better than SAP (p ≤ 0.028 for all).
CONCLUSIONS
High-resolution microperimetry enabled improved performance for detecting glaucomatous damage compared to SAP, highlighting the potential value of fundus-tracking and higher-resolution sampling for the detection of glaucomatous visual field loss.
Keywords
More by Marc G Sarossy
View full profile →Enhanced Detection of Glaucoma Progression Using Widefield Swept-Source OCT.
Test-Retest Variability of Fundus-Tracked Perimetry at the Peripapillary Region in Open Angle Glaucoma.
Photopic Negative Response Obtained Using a Handheld Electroretinogram Device: Determining the Optimal Measure and Repeatability.
Top Research in Visual Field
Browse all →Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Improving our understanding, and detection, of glaucomatous damage: An approach based upon optical coherence tomography (OCT).
In the Knowledge Library
Discussion
Comments and discussion will appear here in a future update.