Purpose
Previous studies have shown a negative correlation between axial length (AL) and pulsatile ocular blood flow (POBF). This relation has been questioned because of the possible confounding effect of ocular volume on ocular rigidity (OR). The purpose of this study was to investigate the relation between AL, as a surrogate parameter for ocular volume, and OR, ocular pulse amplitude (OPA), and POBF.
Methods
Eighty-eight cataract patients were enrolled in this study. A computer-controlled device comprising a microdosimetric pump and a pressure sensor was used intraoperatively. The system was connected to the anterior chamber and used to raise the intraocular pressure (IOP) from 15 to 40 mm Hg, by infusing the eye with a saline solution. After each infusion step, the IOP was continuously recorded for 2 seconds. Blood pressure and pulse rate were measured during the procedure. The OR coefficient was calculated from the pressure volume data. OPA and POBF were measured from pressure recordings.
Results
Median AL was 23.69 (interquartile range 3.53) mm. OR coefficient was 0.0218 (0.0053) μL(-1). A negative correlation between the OR coefficient and AL (ρ = -0.641, P < 0.001) was documented. Increasing AL was associated with decreased OPA (ρ = -0.637, P < 0.001 and ρ = -0.690, P < 0.001) and POBF (ρ = -0.207, P = 0.053 and ρ = -0.238, P = 0.028) at baseline and elevated IOP, respectively.
Conclusions
Based on manometric data, increasing AL is associated with decreased OR, OPA, and POBF. These results suggest decreased pulsatility in high myopia and may have implications on ocular pulse studies and the pathophysiology of myopia.
MeSH Terms
Shields Classification
Related Articles5
Risk Factors for Intraocular Pressure Elevation in Steep Trendelenburg Position During Surgery.
Observational StudyAqueous Humor Antioxidants in Glaucoma: Correlations With Subtypes, Intraocular Pressure, and Medication Use-A Prospective Study.
Case-Control StudyEffect of SPARC Suppression in Mice, Perfused Human Anterior Segments, and Trabecular Meshwork Cells.
Basic ScienceAqueous outflow imaging techniques and what they tell us about intraocular pressure regulation.
ReviewEvaluation of episcleral venous fluid wave during gonioscopy assisted transluminal trabeculotomy in patients with advanced glaucoma.
Observational StudyIs this article assigned to the wrong chapter(s)? Let us know.