Global Search

Search articles, concepts, and chapters

Gillmann Kevin

32 articles in GJC

32 articles in GJC

2.

EYEMATE-SC Trial: Twelve-Month Safety, Performance, and Accuracy of a Suprachoroidal Sensor for Telemetric Measurement of Intraocular Pressure.

Szurman Peter, Gillmann Kevin, Seuthe Anna-Maria, Dick H Burkhard, Hoffmann Esther M, Mermoud Andre et al.

OphthalmologyOct 202219 citationsClinical Trial

The EYEMATE-SC suprachoroidal sensor was studied for continuous IOP monitoring. It proved safe, well-tolerated, and accurately measured IOP for 12 months, offering a promising tool for glaucoma management.

10.

Iridocorneal Angle Assessment After Laser Iridotomy With Swept-source Optical Coherence Tomography.

Meduri Enrico, Gillmann Kevin, Bravetti Giorgio E, Niegowski Letitia J, Mermoud André, Weinreb Robert N et al.

J GlaucomaNov 202010 citationsObservational Study

This study used SS-OCT to measure the anterior chamber angle in narrow-angle eyes before and after laser iridotomy. It found LPI significantly widened the angle, confirming SS-OCT's utility for assessing angle-closure glaucoma treatment.

12.

A Prospective Analysis of iStent Inject Microstent Implantation: Surgical Outcomes, Endothelial Cell Density, and Device Position at 12 Months.

Gillmann Kevin, Mansouri Kaweh, Ambresin Aude, Bravetti Giorgio E, Mermoud André

J GlaucomaAug 202027 citationsProspective Study

iStent inject outcomes were studied for 12 months. Key findings: device protrusion and Schlemm's canal dilation predict success, devices remain stable. Clinical relevance: guides surgical technique for better glaucoma control.

17.

Relationship Between Contact Lens Sensor Output Parameters and Visual Field Progression in Open-angle Glaucoma: Assessment of a Practical Tool to Guide Clinical Risk-assessment.

Gillmann Kevin, Young Cara C, Stanley Jordan, Seibold Leonard K, Hoskens Kirsten, Midha Neha et al.

J GlaucomaJun 20202 citationsRetrospective Study

This study found a contact lens sensor algorithm predicted fast visual field progression in glaucoma comparably to expert clinical assessment, offering a valuable new tool for risk stratification.

20.

Impact of Phacoemulsification Combined with XEN Gel Stent Implantation on Corneal Endothelial Cell Density: 2-Year Results.

Gillmann Kevin, Bravetti Giorgio E, Rao Harsha L, Mermoud André, Mansouri Kaweh

J GlaucomaMar 202036 citationsRetrospective Studies

This study compared corneal endothelial cell loss after combined XEN gel stent and phacoemulsification versus phacoemulsification alone. It found similar, non-significant cell loss, suggesting XEN combined with phacoemulsification is safe for corneal endothelium.

25.

Effect of surgical intraocular pressure lowering on retinal structures - nerve fibre layer, foveal avascular zone, peripapillary and macular vessel density: 1 year results.

Ch'ng Tun Wang, Gillmann Kevin, Hoskens Kirsten, Rao Harsha L, Mermoud André, Mansouri Kaweh

Eye (Lond)Aug 201937 citationsObservational Study

Glaucoma surgery improved macular microcirculation with a delayed response, while peripapillary vessels were IOP-independent. FAZ parameters show promise for assessing vascular reperfusion post-surgery.