Glaucoma Journal Club

In this database

9

2015 โ€“ 2026

DB Citations

65

across indexed articles

h-index

โ€”

Not available

Total Citations

โ€”

Not available

9 articles in Glaucoma Journal Club

Phacoemulsification vs phacoemulsification with micro-bypass stent implantation in primary angle closure and primary angle closure glaucoma: A randomized single-masked clinical study.

Combined phacoemulsification with iStent implantation is associated with a higher likelihood of complete success compared with phacoemulsification alone in eyes with primary angle closure disease at 12 months postoperatively.

Clinical & experimental ophthalmology2020 May41 citations
glaucoma-surgeryiop-medical-therapy

Twenty-four hour intraocular pressure monitoring with the SENSIMED Triggerfish contact lens: effect of body posture during sleep.

Sleep position affects IOP as measured by TF in some patients with progressive glaucoma.

The British journal of ophthalmology2017 Oct20 citations
iop-medical-therapy

Comparative Study of Early Safety and Effectiveness Outcomes of the PreserFlo MicroShunt with and without an Intraluminal Suture Stent.

The use of an intraluminal suture stent in PreserFlo MicroShunt surgery reduces the incidence of early hypotony without compromising surgical success.

Ophthalmology. Glaucoma20253 citations
iop-medical-therapyglaucoma-epidemiology

Impact of Different Intraocular Pressure and Medication Endpoint Criteria on Success Rates in Subconjunctival Minimally Invasive Glaucoma Surgery.

Using different IOP and medication criteria to define success can have a significant influence on the apparent risk of failure, particularly at the 21 mm Hg threshold and when incorporating a minimum 20% IOP reduction from baseline.

Journal of glaucoma2025 Nov 11 citations
glaucoma-surgeryiop-medical-therapy

A Prospective, Real-World, Multicenter Study to Support the Role of Ab-Interno Canaloplasty in Glaucoma Management.

In real-world clinical practice, iTrack canaloplasty significantly reduced IOP and medication burden with a favorable safety profile when performed alone or with phacoemulsification and in diverse glaucoma populations.

American journal of ophthalmology2026 Jan 14
glaucoma-surgery

Online Circular Contrast Perimetry: Validity and Repeatability of Home Performance.

OCCP retains a similar diagnostic accuracy and repeatability in home environments on personal devices compared with clinic-based environments and has the potential to be utilized as a remote tool for glaucoma screening and surveillance.

Journal of glaucoma2025 Nov 1
visual-fieldglaucoma-diagnosis

Flow Test to Predict Early Hypotony and Hypertensive Phase After Ahmed Glaucoma Valve (AGV) Surgical Implantation.

Preoperative OP and CP may predict early hypotony or HP and may be used as a guide as to which AGV valves to discard before implantation surgery.

Journal of glaucoma2016 Jun
iop-medical-therapyglaucoma-diagnosis

Developments in laser trabeculoplasty.

Further large-scale studies are necessary to evaluate the long-term benefits of these newer forms of laser trabeculoplasty. Their initial promising results offer patients with glaucoma additional treatment alternatives.

The British journal of ophthalmology2016 Jan
laser-treatmentiop-medical-therapy

Priming the Ahmed Glaucoma Valve: pressure required and effect of overpriming.

This study demonstrates that the priming pressure is consistent at around 3000 mm Hg. In addition, over-priming is not likely to damage or disturb the closing pressure.

Journal of glaucoma2015
glaucoma-surgery