Glaucoma Journal Club

In this database

28

2020 – 2023

DB Citations

516

across indexed articles

h-index

Not available

Total Citations

Not available

28 articles in Glaucoma Journal Club

Ganglion Cell Complex Thickness and Macular Vessel Density Loss in Primary Open-Angle Glaucoma.

Both GCC thinning and macular vessel density decrease were detectable over time in all diagnostic groups.

Ophthalmology2020 Aug84 citations
oct-imagingglaucoma-progression

Effects of Study Population, Labeling and Training on Glaucoma Detection Using Deep Learning Algorithms.

Deep learning glaucoma detection can achieve high accuracy across diverse datasets with appropriate training strategies.

Translational vision science & technology2020 Apr51 citations
artificial-intelligenceglaucoma-diagnosis

OCT Angiography Artifacts in Glaucoma.

OCTA artifacts associated with poor-quality images are frequent, and their prevalence is affected by ocular and patient characteristics.

Ophthalmology2021 Oct45 citations
visual-fieldoct-imaging

Detecting Glaucoma in the Ocular Hypertension Study Using Deep Learning.

The model's high diagnostic accuracy using OHTS photographs suggests that DL has the potential to standardize and automate POAG determination for clinical trials and management.

JAMA ophthalmology2022 Apr 137 citations
glaucoma-diagnosisvisual-field

Gradient-Boosting Classifiers Combining Vessel Density and Tissue Thickness Measurements for Classifying Early to Moderate Glaucoma.

GBCs that combine OCTA and OCT macula and ONH measurements can improve diagnostic accuracy for glaucoma detection compared to most but not all instrument provided parameters.

American journal of ophthalmology2020 Sep32 citations
oct-imagingoptic-nerve

Diagnostic Ability of Optical Coherence Tomography Angiography Macula Vessel Density for the Diagnosis of Glaucoma Using Difference Scan Sizes.

The diagnostic accuracy of VD using the 6×6 mm macula OCT-A scan was better than the 3×3 mm scan when differentiating between healthy and mild glaucoma eyes, and similar to the 3×3 mm scan when differentiating between healthy…

Journal of glaucoma2020 Apr32 citations
oct-imagingglaucoma-diagnosis

Deep Learning Estimation of 10-2 and 24-2 Visual Field Metrics Based on Thickness Maps from Macula OCT.

Deep learning models improved estimates of functional loss from SD OCT imaging. Accurate estimates can help clinicians to individualize VF testing to patients.

Ophthalmology2021 Nov25 citations
visual-fieldoptic-nerve

Agreement Between 10-2 and 24-2C Visual Field Test Protocols for Detecting Glaucomatous Central Visual Field Defects.

Substantial agreement for identifying CVFDs using the 24-2C and 10-2 protocols suggests that combining tests by adding central test points to the 24-2 test grid may supplant the need for 2 perimetry regimens for detecting…

Journal of glaucoma2021 Jun 124 citations
visual-fieldglaucoma-diagnosis

Superficial and Deep Macula Vessel Density in Healthy, Glaucoma Suspect, and Glaucoma Eyes.

SCP vessel densities have better diagnostic accuracy for detecting glaucoma than DCP vessel densities. Although the diagnostic accuracy of the macula SCP is relatively modest, it is more informative than the DCP.

Journal of glaucoma2021 Jun 123 citations
glaucoma-diagnosisoptic-nerve

Standard Reliability and Gaze Tracking Metrics in Glaucoma and Glaucoma Suspects.

GT metrics do not have a clinically significant association with standard reliability metrics.

American journal of ophthalmology2022 Feb20 citations
visual-fieldglaucoma-diagnosis

Macular Thickness and Microvasculature Loss in Glaucoma Suspect Eyes.

Whereas the rate of GCC thinning was faster on average in suspect eyes than in healthy eyes, some suspect eyes showed significant loss of vessel density and faster vessel density loss than GCC thinning.

Ophthalmology. Glaucoma202215 citations
oct-imagingiop-medical-therapy

Multilayer Macula Vessel Density and Visual Field Progression in Glaucoma.

Lower macular SVD, and not DVD, was associated with a higher probability of past VF progression.

American journal of ophthalmology2022 May14 citations
glaucoma-progressionvisual-field

Estimated Utility of the Short-term Assessment of Glaucoma Progression Model in Clinical Practice.

In this cohort study, results from the STAGE model with reduction of the rate of progression as the end point, frequent testing, and a moderate effect size, suggest that clinical trials to test efficacy of…

JAMA ophthalmology2021 Aug 113 citations
optic-nervevisual-field

A Deep Learning Approach to Improve Retinal Structural Predictions and Aid Glaucoma Neuroprotective Clinical Trial Design.

Our deep learning models were able to accurately estimate both macula GCIPL and ONH RNFL hemiretinal thickness.

Ophthalmology. Glaucoma202312 citations
optic-nerveglaucoma-progression

Bruch Membrane Opening Detection Accuracy in Healthy Eyes and Eyes With Glaucoma With and Without Axial High Myopia in an American and Korean Cohort.

As BMO location inaccuracy was 2.4 times more likely in eyes with high axial myopia regardless of diagnosis, optical coherence tomography images of high myopes should be reviewed carefully, and when possible, BMO location should…

American journal of ophthalmology2022 May12 citations
optic-nerveoct-imaging

Impact of Pupil Dilation on Optical Coherence Tomography Angiography Retinal Microvasculature in Healthy Eyes.

Pupil dilation using topical 2.5% phenylephrine and 0.5% tropicamide results in a small but statistically significant reduction in non-HD ONH whole image and cpCD in healthy eyes.

Journal of glaucoma2020 Nov10 citations
oct-imagingoptic-nerve

Measurements of OCT Angiography Complement OCT for Diagnosing Early Primary Open-Angle Glaucoma.

Associations between capillary density and visual function were found in the regions known to be at highest risk for damage in preperimetric glaucoma eyes and all regions of mild glaucoma eyes.

Ophthalmology. Glaucoma20229 citations
iop-medical-therapyoptic-nerve

Longitudinal Structure-Function Relationship between Macular Vessel Density and Thickness and Central Visual Field in Early Glaucoma.

Rates of VD loss and GCC thinning are associated with central VF loss over time. Assessment of both macular VD and GCC thickness should be considered for evaluation of glaucoma progression.

Ophthalmology. Glaucoma20229 citations
visual-fieldglaucoma-progression

Diurnal Variation of Retinal Vessel Density in Healthy Human Eyes.

There was a small increase in ONH VD, but not macular VD, in the evening compared with the morning in healthy human eyes.

Journal of glaucoma2021 Sep 19 citations
oct-imagingoptic-nerve

Effect of Testing Frequency on the Time to Detect Glaucoma Progression With Optical Coherence Tomography (OCT) and OCT Angiography.

The time required to detect a statistically significant negative cpRNFL and cpCD slope decreased as the testing frequency increased, albeit not proportionally.

American journal of ophthalmology2023 Jan7 citations
oct-imagingoptic-nerve

Racial Differences in the Rate of Change in Anterior Lamina Cribrosa Surface Depth in the African Descent and Glaucoma Evaluation Study.

Glaucomatous remodeling of the lamina cribrosa differs between AD and ED patients with glaucoma.

Investigative ophthalmology & visual science2021 Apr 16 citations
glaucoma-progressionvisual-field

Progressive Thinning of Retinal Nerve Fiber Layer and Ganglion Cell-Inner Plexiform Layer in Glaucoma Eyes with Disc Hemorrhage.

The rate of mGCIPL and cpRNFL thinning was faster in DH eyes than non-DH eyes.

Ophthalmology. Glaucoma20216 citations
optic-nervevisual-field

The Association Between Regional Macula Vessel Density and Central Visual Field Damage in Advanced Glaucoma Eyes.

Given a stronger MVD-central 10-degree VF association compared with GCC, as well as stronger GCC-central 5-degree VF association compared with MVD, MVD and GCC are complementary measurements in eyes with advanced glaucoma.

Journal of glaucoma2022 Sep 15 citations
visual-fieldoct-imaging

Rates of Circumpapillary Retinal Nerve Fiber Layer Thinning and Capillary Density Loss in Glaucomatous Eyes with Disc Hemorrhage.

Mean rates of vessel density loss between DH and non-DH eyes were different not only in the affected area but also in the other regions.

American journal of ophthalmology2022 Mar5 citations
optic-nerveoct-imaging

Dry Eye Symptom Severity and Visual Field Reliability Metrics.

A total of 494 patients completed the 5-item Dry Eye Questionnaire and VF testing.

Journal of glaucoma2022 May 14 citations
visual-field

Association between Rates of Retinal Nerve Fiber Layer Thinning after Intraocular Pressure-Lowering Procedures and Disc Hemorrhage.

POAG or glaucoma suspect eyes with a history of DH should be carefully followed after IOP-lowering procedures.

Ophthalmology. Glaucoma20203 citations
optic-nerveiop-medical-therapy

Agreement between Compass Fundus Perimeter New Grid and 10-2 Testing Protocols for Detecting Central Visual Field Defects.

Although the Compass NG detected fewer CVFDs than the 10-2 test protocol, it did detect CVFDs that were not observed in the Compass 24-2 test in patients with early glaucoma.

Ophthalmology. Glaucoma20222 citations
visual-fieldglaucoma-diagnosis

Rates of Retinal Nerve Fiber Layer Thinning in Distinct Glaucomatous Optic Disc Phenotypes in Early Glaucoma.

Rates of cpRNFL thinning were different among the 4 glaucomatous optic disc phenotypes.

American journal of ophthalmology2021 Sep2 citations
optic-nerveoct-imaging