Risk Factors and Long-Term Outcomes in Patients with Low Intraocular Pressure after Trabeculectomy.
Victoria L Tseng, Carole H Kim, Pablo T Romero, Fei Yu, Kenneth W Robertson-Brown, Lam Phung, Daniel Raygoza, Joseph Caprioli, Anne L Coleman
Summary
The absence of laser suture lysis and surgeon are factors potentially associated with low IOP after trabeculectomy. Numeric hypotony does not necessarily represent clinical failure after trabeculectomy.
Abstract
PURPOSE
To examine risk factors for low intraocular pressure (IOP) after trabeculectomy and to describe long-term outcomes in these eyes.
DESIGN
Retrospective case-control study.
PARTICIPANTS
Cases with low IOP included all patients with IOP ≤5 mmHg on 3 or more consecutive visits 3 months or later after trabeculectomy. Control patients without low IOP after trabeculectomy were randomly selected at a 1:2 case-to-control ratio.
METHODS
A case-control study was performed of patients undergoing trabeculectomy at the Stein Eye Institute. Covariates included demographics, history of cataract surgery, refractive error, number of glaucoma medications, family history of glaucoma, diabetes, hypertension, visual acuity (VA), IOP, number of sutures in the scleral flap, laser suture lysis, surgeon, and laterality of surgery. Logistic regression modeling was used to examine associations between each covariate and low IOP. Postoperative outcomes that were examined included reoperation, vision loss, and surgical failure. The time between trabeculectomy and each outcome was compared between cases and controls with Cox proportional hazards regression modeling.
MAIN OUTCOME MEASURES
Low IOP after trabeculectomy, reoperation, vision loss, and surgical failure.
RESULTS
Of 3659 total trabeculectomies performed by 5 surgeons between 1990 and 2013, 64 eyes had low IOP (1.7%), which were compared with 130 control eyes. Fifteen of the 64 eyes with low IOP had hypotony maculopathy (23.4%). After accounting for differences in baseline IOP, laser suture lysis was negatively correlated with low IOP after trabeculectomy (odds ratio [OR], 0.33; 95% confidence interval [CI], 0.13-0.87); surgeon was correlated with high vs. low IOP after trabeculectomy (OR, 5.32; 95% CI, 1.53-18.52). There were no statistically significant associations between low IOP and time to reoperation (hazard ratio [HR], 0.73; 95% CI, 0.32-1.68), vision loss (HR, 1.77; 95% CI, 0.81-3.88) or surgical failure (HR, 1.14; 95% CI, 0.62-2.11). In patients with low IOP, there was a higher unadjusted incidence of bleb revision in patients who had maculopathy (7.6 vs. 1.9 revisions/100 person-years; for maculopathy versus no maculopathy P = 0.008).
CONCLUSIONS
The absence of laser suture lysis and surgeon are factors potentially associated with low IOP after trabeculectomy. Numeric hypotony does not necessarily represent clinical failure after trabeculectomy.
More by Victoria L Tseng
View full profile →Association of Dietary Fatty Acid Intake With Glaucoma in the United States.
Frequency of a diagnosis of glaucoma in individuals who consume coffee, tea and/or soft drinks.
Association between Exercise Intensity and Glaucoma in the National Health and Nutrition Examination Survey.
Top Research in Glaucoma Surgery
Browse all →Treatment Outcomes in the Primary Tube Versus Trabeculectomy Study after 1 Year of Follow-up.
Efficacy, Safety, and Risk Factors for Failure of Standalone Ab Interno Gelatin Microstent Implantation versus Standalone Trabeculectomy.
Prospective, Randomized, Controlled Pivotal Trial of an Ab Interno Implanted Trabecular Micro-Bypass in Primary Open-Angle Glaucoma and Cataract: Two-Year Results.
Discussion
Comments and discussion will appear here in a future update.