Relationship of Corneal Hysteresis and Anterior Lamina Cribrosa Displacement in Glaucoma.
Brandon J Wong, Sasan Moghimi, Linda M Zangwill, Mark Christopher, Akram Belghith, Eren Ekici, Christopher Bowd, Massimo A Fazio, Christopher A Girkin, Robert N Weinreb
Summary
Lower corneal hysteresis was significantly associated with posterior displacement of the anterior lamina cribrosa over time. These data provide additional support for lower corneal hysteresis being a risk factor for glaucoma progression.
Abstract
PURPOSE
To investigate the relationship between corneal hysteresis (CH) and anterior lamina cribrosa surface (ALCS) displacement over time in a cohort of patients with glaucoma.
DESIGN
Prospective observational case series.
METHODS
In this study, 147 eyes from 96 glaucoma or glaucoma suspect patients were followed for a mean of 3.5 years and 7.9 visits. Baseline CH measurements were obtained using the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments Inc, Depew, New York, USA). The mean anterior lamina cribrosa surface depth (ALCSD) and choroidal thickness were by automated segmentation of spectral-domain optical coherence tomography (SD-OCT) scans. The rate of change of ALCSD was calculated using linear mixed effects models. Relationship between baseline CH and follow-up ALCSD rate of change was adjusted for confounding factors, including age, intraocular pressure (IOP), and choroidal thickness.
RESULTS
The mean baseline CH was 9.4 mm Hg (95% confidence interval [CI] 9.1-9.7). Overall, the ALCS was displaced posteriorly at a rate of 0.78 μm/y (95% CI -1.82, 0.26). Seventeen eyes (11.5%) showed a significant posterior displacement of ALCS, whereas 22 eyes (15.0%) showed a significant anterior displacement of ALCS. The choroidal thickness thinned at a rate of -1.09 μm/y during the follow-up (P = .001). Multivariable mixed modeling showed that choroidal thinning, lower IOP change, and lower corneal hysteresis were significantly associated with posterior ALCS displacement over time (P = .034, P = .037, and P = .048). Each 1 mm lower CH was associated with 0.66 μm/y posterior displacement of the ALCS.
CONCLUSIONS
Lower corneal hysteresis was significantly associated with posterior displacement of the anterior lamina cribrosa over time. These data provide additional support for lower corneal hysteresis being a risk factor for glaucoma progression.
More by Brandon J Wong
View full profile →Glaucoma Expert-Level Detection of Angle Closure in Goniophotographs With Convolutional Neural Networks: The Chinese American Eye Study.
Hemiretinal Asymmetry in Peripapillary Vessel Density in Healthy, Glaucoma Suspect, and Glaucoma Eyes.
Effectiveness of Glaucoma Screening and Factors Associated with Follow-up Adherence among Glaucoma Suspects in a Safety-Net Teleretinal Screening Program.
Top Research in IOP & Medical Therapy
Browse all →The Complications of Myopia: A Review and Meta-Analysis.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Treatment Outcomes in the Primary Tube Versus Trabeculectomy Study after 1 Year of Follow-up.
Discussion
Comments and discussion will appear here in a future update.