Evaluation of the Diagnostic Performance of Swept-Source Anterior Segment Optical Coherence Tomography in Primary Angle Closure Disease.
Ping Ma, Yanyan Wu, Julius Oatts, Jutima Patlidanon, Yinxi Yu, Gui-Shuang Ying, Brad Kline, Tin A Tun, Mingguang He, Tin Aung, Shuning Li, Yangfan Yang, Ying Han
Summary
SS-OCT of the anterior segment showed excellent diagnostic performance distinguishing PACD from normal eyes and moderate diagnostic ability distinguishing eyes with PAC/PACG from eyes with PACS.
Abstract
PURPOSE
To evaluate the diagnostic performance of swept-source anterior segment optical coherence tomography (SS-OCT) in differentiating eyes with primary angle closure disease (PACD) from eyes of control subjects, as well as eyes with PAC and PAC glaucoma (PACG) from eyes with PAC suspect (PACS) disease.
DESIGN
Multicenter cross-sectional study.
METHODS
Chinese patients were classified into control, PACS, and PAC/PACG groups. The area under the receiving operating characteristic curve (AUC) from logistic regression models was used to evaluate discriminating ability. Sensitivity and specificity were calculated, and performance of the models was validated using an independent dataset.
RESULTS
A total of 2928 SS-OCT images from 366 eyes of 260 patients were recruited to develop diagnostic models. The validation dataset included 1176 SS-OCT images from 147 eyes of 143 patients. For distinguishing PACD from control eyes, average anterior chamber depth had the highest AUC (0.94). With a cutoff of 2.2 mm for average anterior chamber depth, the sensitivity and specificity were 90.2% and 85.2% in the training set. For distinguishing PAC/PACG from PACS, a multivariate model had an AUC of 0.83, with sensitivity and specificity of 82.0% and 62.8% in the training set. The validation set confirmed the findings.
CONCLUSIONS
SS-OCT of the anterior segment showed excellent diagnostic performance distinguishing PACD from normal eyes and moderate diagnostic ability distinguishing eyes with PAC/PACG from eyes with PACS. ACD alone may provide a simple and effective way to diagnose PACD from control subjects. As ACD can be obtained using other more available modalities, this has implications for the early diagnosis of PACD.
More by Ping Ma
View full profile →Top Research in Diagnosis & Screening
Browse all →Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs.
Dry eye disease and oxidative stress.
Central Corneal Thickness in the Ocular Hypertension Treatment Study (OHTS).
In the Knowledge Library
Discussion
Comments and discussion will appear here in a future update.