The Structural Layers of the Porcine Iris Exhibit Inherently Different Biomechanical Properties.
Royston K Y Tan, Satish K Panda, Fabian A Braeu, Arumugam R Muralidharan, Monisha E Nongpiur, Anita S Y Chan, Tin Aung, Raymond P Najjar, Michaël J A Girard
Summary
We have established a new protocol to evaluate the biomechanical properties of the structural layers of the iris.
Abstract
PURPOSE
The purpose of this study was to isolate the structural components of the ex vivo porcine iris tissue and to determine their biomechanical properties.
METHODS
The porcine stroma and dilator tissues were separated, and their dimensions were assessed using optical coherence tomography (OCT). The stroma underwent flow test (n = 32) to evaluate for permeability using Darcy's Law (ΔP = 2000 Pa, A = 0.0391 mm2), and both tissues underwent stress relaxation experiments (ε = 0.5 with initial ramp of δε = 0.1) to evaluate for their viscoelastic behaviours (n = 28). Viscoelasticity was characterized by the parameters β (half width of the Gaussian distribution), τm (mean relaxation time constant), E0 (instantaneous modulus), and E∞ (equilibrium modulus).
RESULTS
For the stroma, the hydraulic permeability was 9.49 ± 3.05 × 10-6 mm2/Pa · s, and the viscoelastic parameters were β = 2.50 ± 1.40, and τm = 7.43 ± 4.96 s, with the 2 moduli calculated to be E0 = 14.14 ± 6.44 kPa and E∞ = 6.08 ± 2.74 kPa. For the dilator tissue, the viscoelastic parameters were β = 2.06 ± 1.33 and τm = 1.28 ± 1.27 seconds, with the 2 moduli calculated to be E0 = 9.16 ± 3.03 kPa and E∞ = 5.54 ± 1.98 kPa.
CONCLUSIONS
We have established a new protocol to evaluate the biomechanical properties of the structural layers of the iris. Overall, the stroma was permeable and exhibited smaller moduli than those of the dilator muscle. An improved characterization of iris biomechanics may form the basis to further our understanding of angle closure glaucoma.
More by Royston K Y Tan
View full profile →Changes in Iris Stiffness and Permeability in Primary Angle Closure Glaucoma.
Are Macula or Optic Nerve Head Structures Better at Diagnosing Glaucoma? An Answer Using Artificial Intelligence and Wide-Field Optical Coherence Tomography.
Iris Morphological and Biomechanical Factors Influencing Angle Closure During Pupil Dilation.
Top Research in OCT & Imaging
Browse all →Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications.
Deep learning in ophthalmology: The technical and clinical considerations.
Anterior segment optical coherence tomography.
In the Knowledge Library
Discussion
Comments and discussion will appear here in a future update.