Increased iris thickness and association with primary angle closure glaucoma.
Wang B-S, Narayanaswamy A, Amerasinghe N, Zheng C, He M, Chan Y-H, Nongpiur M E, Friedman D S, Aung T
AI Summary
This study found increased iris thickness is significantly associated with angle closure glaucoma. This suggests iris thickness may be a useful biomarker for identifying individuals at risk.
Abstract
Aims
To investigate the relationship between quantitative iris parameters and angle closure disease. methods: Participants with angle closure were recruited prospectively from glaucoma clinics. Anterior segment optical coherence tomography (AS-OCT) was performed under standardised dark conditions. Customised software was used on horizontal AS-OCT scans to measure iris thickness at 750 um (IT750) and 2000 um (IT2000) from the sclera spur, maximal iris thickness (ITM) and cross-sectional area of the iris (I-Area).
Results
167 Angle closure (consisting of 50 primary angle-closure (PAC), 73 primary angle closure glaucoma (PACG) and 44 fellow eyes of acute PAC) and 1153 normal participants were examined. After adjusting for age, sex, pupil size and anterior chamber depth, mean IT750 (0.499 vs 0.451 mm, p<0.001), IT2000 (0.543 vs 0.479 mm, p<0.001), ITM (0.660 vs 0.602 mm, p<0.001) and I-Area (1.645 vs 1.570 mm(2), p=0.014) were significantly greater in angle closure (combined groups) versus normal eyes. Multivariate adjusted odd ratios (OR) of each parameter for the angle closure as compared with normal eyes were: IT750 OR1.7 (95% CI 1.1 to 2.7, p=0.032); IT2000 OR2.2 (95% CI 1.3 to 3.8, p=0.006) and ITM OR2.2 (95% CI 1.3 to 3.6, p=0.003), respectively, per 0.1 unit increase.
Conclusions
Increased iris thickness is associated with angle closure.
MeSH Terms
Shields Classification
Related Articles5
Acute Angle Closure Incidence in a Large Countywide Safety Net Teleretinal Screening Program.
Cohort StudyPrimary angle-closed diseases recognition through artificial intelligence-based anterior segment-optical coherence tomography imaging.
Cross-Sectional StudyInvestigating the determinants of iridolenticular contact area: a novel parameter for angle closure.
Cross-Sectional StudyDeep learning-based normative database of anterior chamber dimensions for angle closure assessment: the Singapore Chinese Eye Study.
Cross-Sectional StudyRefractive Error and Anterior Chamber Depth as Risk Factors in Primary Angle Closure Disease: The Chinese American Eye Study.