Acta OphthalmolMarch 201121 citations

Retinal nerve fibre layer thickness in full-term children assessed with Heidelberg retinal tomography and optical coherence tomography: normal values and interocular asymmetry.

Larsson Eva, Eriksson Urban, Alm Albert


AI Summary

This study found OCT provides more consistent retinal nerve fiber layer thickness measurements than HRT in healthy children (5-16 years), making it more reliable for detecting optic nerve disease.

Abstract

Purpose

This study aimed to investigate normal values and interocular differences in retinal nerve fibre layer (RNFL) thickness, using optical coherence tomography (OCT) and Heidelberg retinal tomography (HRT), in 5-16-year-old children born at full-term with normal birthweights.

Methods

Fifty-six children with normal visual acuity and refraction were examined with Stratus OCT and HRT. Three examinations were performed in each eye. One eye in each child was randomized for analyses of normal values. Findings in 54 eyes were evaluated. Mean values of RNFL thickness were calculated. Coefficients of variance and intraclass correlations were calculated. The correlation between right and left eyes and the limits of difference were determined for both methods.

Results

Mean RNFL thickness was 98.4 μm (standard deviation [SD] 7.88 μm) assessed with OCT and 213.0 μm (SD 54.0 μm) assessed with HRT. No correlations between age or gender and RNFL thickness were found. The coefficients of variance were 2.9% and 5.6% for OCT and HRT, respectively, and intraclass correlations were 0.85 and 0.88, respectively. The limits of difference between the two eyes ranged from -9 μm to 9 μm with OCT and from -109 μm to 87 μm with HRT.

Conclusions

Both OCT and HRT can be used in children aged 5-16 years, but OCT provides less variability in determinations of RNFL thickness, both in repeated examinations of the same eye and in comparisons between the two eyes. The present study provides values for normal RNFL thickness in healthy children which can be used to make comparisons with values in children with optic nerve diseases.


MeSH Terms

AdolescentBirth WeightChildChild, PreschoolDiagnostic Techniques, OphthalmologicalFemaleGestational AgeHumansMaleNerve FibersOptic DiskReference ValuesRetinal Ganglion CellsTomography, Optical CoherenceVisual Acuity