In vivo confocal microscopy and ultrasound biomicroscopy study of filtering blebs after trabeculectomy: limbus-based versus fornix-based conjunctival flaps.
Morita Koji, Gao Yanlin, Saito Yoshiaki, Higashide Tomomi, Kobayashi Akira, Ohkubo Shinji, Sugiyama Kazuhisa
AI Summary
This study found successful glaucoma filtering blebs formed differently based on limbus- or fornix-based conjunctival flaps, impacting how bleb function is assessed via imaging.
Abstract
Purpose
To evaluate morphological features of filtering blebs after trabeculectomy with limbus-based versus fornix-based conjunctival flaps (LBCF and FBCF, respectively) using in vivo confocal microscopy (IVCM) and ultrasound biomicroscopy (UBM).
Patients and methods: Seventy-five eyes of 62 patients with glaucoma were recruited. Thirty-eight eyes of 31 patients received trabeculectomy with LBCF and 37 eyes of 34 patients received trabeculectomy with FBCF. Successful bleb was defined as postoperative intraocular pressure (IOP) ≤15 mm Hg and IOP reduction ≥20% without antiglaucoma medication. Microcyst number, density of subepithelial connective tissue, and vascularity of subepithelial tissue were evaluated by IVCM. Bleb reflectivity, the route under the scleral flap, bleb height, and height of fluid-filled space were examined by UBM.
Results
On the basis of IOP criteria, 79% (30 of 38 blebs) of the LBCF group and 70% (26 of 37 blebs) of the FBCF group were defined as successful blebs (P=0.28). Compared with the successful FBCF group, the successful LBCF group had a larger microcyst number (P<0.001), lower density of subepithelial connective tissue (P=0.046), greater avascularity of subepithelial tissue (P=0.024), and higher height of fluid-filled space (P=0.017). No morphological differences between LBCF and FBCF groups were found in failed blebs.
Conclusions
Morphological features of successful blebs in IVCM and UBM were different between blebs with LBCF and FBCF. Type of conjunctival flaps should be considered when estimating the bleb function based on bleb morphology examined with these imaging devices.
MeSH Terms
Shields Classification
Related Articles5
Visualization of Scleral Flap Patency in Glaucoma Filtering Blebs Using OCT.
Cross-Sectional StudyAhmed's sub-flap mattress suture deep sclerectomy assessment with Ultrasound Biomicroscopy.
Randomized Controlled TrialBleb vessel density as a predictive factor for surgical revisions after Preserflo Microshunt implantation.
Clinical TrialUsefulness of Eye Deformation in the Corvis ST Measurement to Predict Postoperative Hypotony Complications in Glaucoma.
Cohort StudyFactors Correlated With Mid-Term Morphology of Functional Blebs Following Implantation of Preserflo MicroShunt Using AS-OCT.