1.
Iris Morphological and Biomechanical Factors Influencing Angle Closure During Pupil Dilation.
Tan Royston K Y, Ng Gim Yew, Tun Tin A, Braeu Fabian A, Nongpiur Monisha E, Aung Tin et al.
Invest Ophthalmol Vis SciSep 20247 citationsBasic Science
Finite element analysis showed iris thickness, convexity, stiffness, and anterior chamber dimensions significantly influence angle narrowing during pupil dilation, guiding risk assessment for angle-closure glaucoma.