19 articles in Glaucoma Journal Club
Deep-learning Classifier With an Ultrawide-field Scanning Laser Ophthalmoscope Detects Glaucoma Visual Field Severity.
Despite using an ultrawide-field scanning laser ophthalmoscope, DL can detect glaucoma characteristics and glaucoma visual field defect severity with high reliability.
Comparison of the Intraocular Pressure Measured Using the New Rebound Tonometer Icare ic100 and Icare TA01i or Goldmann Applanation Tonometer.
The new rebound tonometer Icare ic100 almost constantly showed IOPs lower than GAT. The difference was affected by CCT, corneal curvature, and disease.
The Relationship Between Corvis ST Tonometry Parameters and Ocular Response Analyzer Corneal Hysteresis.
CST parameters are significant, but weakly or moderately, related to ORA measured CH.
Association between Corneal Biomechanical Properties with Ocular Response Analyzer and Also CorvisST Tonometry, and Glaucomatous Visual Field Severity.
Glaucomatous VF severity was best described by both ORA and CST parameters.
Repeatability of the Novel Intraocular Pressure Measurement From Corvis ST.
The bIOP showed a better prevision and repeatability for IOP measurement.
The Relationship between the Waveform Parameters from the Ocular Response Analyzer and the Progression of Glaucoma.
Ocular Response Analyzer waveform parameters were correlated significantly with glaucomatous VF progression and showed a stronger than correlation with VF progression than CH.
The Relationship Between Corneal Hysteresis and Progression of Glaucoma After Trabeculectomy.
CH is a useful measure in the management of glaucoma after trabeculectomy.
Evaluation of Automatic Monitoring of Instillation Adherence Using Eye Dropper Bottle Sensor and Deep Learning in Patients With Glaucoma.
The eye dropper bottle sensor system developed by us can be used for automatic monitoring of instillation adherence in patients with glaucoma.
Development of a Novel Corneal Concavity Shape Parameter and Its Association with Glaucomatous Visual Field Progression.
A novel corneal concavity shape parameter, CSI, was closely related to glaucomatous VF progression.
Iris Thickness and Severity of Neovascular Glaucoma Determined Using Swept-Source Anterior-segment Optical Coherence Tomography.
IT decreases with the progression of the NVG stage and is thinnest in 360-degree AC-NVG patients. Our study suggests a new morphologic feature of NVG.
Comment on Cataract Surgery and Rate of Visual Field Progression in Primary Open-Angle Glaucoma.
Outcomes of Wider Area Bleb Revision Using Bleb Knife With Adjunctive Mitomycin C.
Wider area bleb revision using bleb knife with adjunctive MMC had a good success rate, according to strict success criteria, except in patients with NVG.
Glaucoma Implant Tube Lumen Obstruction Visualized Using Anterior Segment Optical Coherence Tomography.
We then refixed the tube at the same place and achieved good IOP control after the surgery. Our findings indicate that ASOCT is useful for diagnosing glaucoma implant tube lumen obstruction and surgical decision-making.
Usefulness of Eye Deformation in the Corvis ST Measurement to Predict Postoperative Hypotony Complications in Glaucoma.
A careful attention should be paid to the occurrence of hypotony maculopathy with male gender and greater highest concavity deflection Amplitude despite higher preoperative GAT IOP.
Usefulness of Intraocular Pressure With the Ocular Response Analyzer to Predict Postoperative Hypotony Complications in Glaucoma.
Higher preoperative IOPcc and pseudophakia were significant predictors of the occurrence of hypotony complications.
Factors Affecting Bleb Morphology and Postoperative Intraocular Pressure in Inferotemporal PreserFlo MicroShunt Implantation.
Although inferotemporal PreserFlo may result in avascular blebs in a small proportion of patients, postoperative IOP is associated primarily with age rather than with bleb morphology.
A Pilot Evaluation Assessing the Ease of Use and Accuracy of the New Self/Home-Tonometer IcareHOME in Healthy Young Subjects.
The IcareHOME can be used as a self/home-tonometer; however, it may result in lower IOP values.
Intradevice and Interdevice Agreement Between a Rebound Tonometer, Icare PRO, and the Tonopen XL and Kowa Hand-held Applanation Tonometer When Used in the Sitting and Supine Position.
The repeatability of Icare PRO was slightly lower in the supine position than in the sitting position.
Hypotony maculopathy obtained by retro-mode retinal imaging.