Angle widening and alteration of ciliary process configuration after cataract surgery for primary angle closure.
Nonaka Atsushi, Kondo Takehisa, Kikuchi Masashi, Yamashiro Kenji, Fujihara Masashi, Iwawaki Takuji, Yamamoto Kaoruko, Kurimoto Yasuo
AI Summary
Cataract surgery in angle closure eyes significantly widened the angle and moved ciliary processes backward, improving outflow. This shows cataract removal offers more than just lens volume reduction.
Abstract
Purpose
To evaluate quantitatively, by means of ultrasound biomicroscopy (UBM), changes in the anterior segment configuration, including the ciliary processes, induced by cataract surgery in eyes with primary angle closure.
Design
Retrospective interventional case series.
Participants
Thirty-one eyes of 31 patients with primary angle closure or primary angle-closure glaucoma were treated with cataract surgery. Before cataract surgery, 10 eyes had been treated with laser peripheral iridotomy, and 1 with laser peripheral iridoplasty.
Methods
Configuration of the anterior chamber was examined by means of UBM before and at 3 months after cataract surgery.
Main outcome measures
Using UBM, anterior chamber depth (ACD), angle opening distance at points 500 mum from the scleral spur (AOD500), and trabecular-ciliary process distance (TCPD) were measured.
Results
Not only ACD and AOD500, but also TCPD, increased significantly after cataract surgery, compared with measurements obtained before surgery (P<0.001). Postoperative AOD500 was correlated significantly with postoperative TCPD (r = 0.72, P<0.001) and with the amount of change of TCPD caused by cataract surgery (Delta TCPD) (r = 0.52, P<0.01).
Conclusions
Cataract surgery attenuated anterior positioning of the ciliary processes in eyes with primary angle closure, concomitant with significant widening of the angle. Cataract surgery resulted in not only complete dissolution of lens volume and pupillary block, but also attenuation of the anterior positioning of the ciliary processes, all of which contributed to postoperative widening of the angle in eyes with primary angle closure.
MeSH Terms
Shields Classification
Related Articles5
Changes in anterior chamber angle width and depth after intraocular lens implantation in eyes with glaucoma.
Observational StudyAnterior chamber parameters measured using the Pentacam Scheimpflug imaging device before and after cataract surgery in eyes with primary angle closure.
Retrospective StudiesDetermination of anterior segment changes with Pentacam after phacoemulsification in eyes with primary angle-closure glaucoma.
Clinical TrialAnterior Chamber Angle Changes in Primary Angle-closure Glaucoma Following Phacoemulsification Versus Phacotrabeculectomy: A Prospective Randomized Clinical Trial.
Randomized Controlled TrialFactors affecting refractive outcome after cataract surgery in primary angle-closure glaucoma.
Cross-Sectional StudyIs this article assigned to the wrong chapter(s)? Let us know.