Spectral-domain optical coherence tomographic assessment of Schlemm's canal in Chinese subjects with primary open-angle glaucoma.
Hong Jiaxu, Xu Jianjiang, Wei Anji, Wen Wen, Chen Junyi, Yu Xibao, Sun Xinghuai
AI Summary
SD-OCT showed primary open-angle glaucoma patients have a smaller Schlemm's canal area, correlating with higher intraocular pressure. This suggests SC morphology impacts glaucoma, aiding future diagnostic/treatment strategies.
Abstract
Purpose
To evaluate in vivo features of Schlemm's canal (SC) in patients with primary open-angle glaucoma (POAG) with spectral-domain optical coherence tomography (SD-OCT) and to investigate the relationship of SC size with intraocular pressure (IOP) and glaucoma severity.
Design
Prospective, comparative study.
Participants
Fifty Chinese patients with newly diagnosed POAG who had not undergone surgery and 50 normal Chinese subjects from a population-based, cross-sectional study in Shanghai.
Methods
All participants underwent SD-OCT. The diameter and area of SC were examined in the temporal and nasal sections and measured with customized software.
Main outcome measures
Patient demographics, repeatability and reproducibility assessed with the coefficient of variation (CV) and the intraclass correlation coefficient (ICC), SC parameters and their correlation with IOP, and the mean deviation (MD) of the visual field were analyzed.
Results
The percentage of sections in which SC was observable was similar between eyes with POAG and normal eyes, and ranged from 78% to 86%. For intraobserver repeatability, the CV and ICC values were 7.9% and 0.97 for diameter, and 13.8% and 0.83 for area, respectively. For interobserver repeatability, the CV and ICC values were 13.6% and 0.89 for diameter, and 13.4% and 0.80 for area, respectively. Significant differences between the 2 groups were found for the average SC area (11332 ± 2015 μm(2) vs. 13991 ± 1357 μm(2); P<0.001), but not for the SC diameter (40.2 ± 7.1 μm vs. 45.2 ± 4.0 μm; P = 0.195). In addition, the mean IOP values correlated well only with the SC area (ρ = -0.674, P<0.001), not with the SC diameter (ρ = -0.103, P = 248). No significant correlations were found between the MD values and the SC parameters.
Conclusions
Eyes with POAG have a decreased SC area compared with normal eyes. A correlation between the SC area and the IOP also was observed. However, the degree of glaucoma damage was not consistently associated with the SC area. Spectral-domain OCT could be used for investigating SC changes in patients with glaucoma.
MeSH Terms
Shields Classification
Related Articles5
Comparison of intraocular pressure profiles during the water drinking test and the modified diurnal tension curve.
Observational StudyCorvis Biomechanical Factor Facilitates the Detection of Primary Angle Closure Glaucoma.
Cross-Sectional StudyReduced Pulsatile Trabecular Meshwork Motion in Eyes With Primary Open Angle Glaucoma Using Phase-Sensitive Optical Coherence Tomography.
Cross-Sectional StudyChanges in Intraocular Pressure and Angle Structure after Dilation in Primary Angle-Closure Suspects with Visually Significant Cataract.
Observational StudyTowards 'automated gonioscopy': a deep learning algorithm for 360° angle assessment by swept-source optical coherence tomography.
Cross-Sectional StudyIs this article assigned to the wrong chapter(s)? Let us know.