Aqueous Angiography-Mediated Guidance of Trabecular Bypass Improves Angiographic Outflow in Human Enucleated Eyes.
Huang Alex S, Saraswathy Sindhu, Dastiridou Anna, Begian Alan, Mohindroo Chirayu, Tan James C H, Francis Brian A, Hinton David R, Weinreb Robert N
AI Summary
In human enucleated eyes, trabecular bypass stents placed in areas initially lacking aqueous outflow significantly improved outflow as shown by angiography, suggesting targeted glaucoma treatment potential.
Abstract
Purpose
To assess the ability of trabecular micro-bypass stents to improve aqueous humor outflow (AHO) in regions initially devoid of AHO as assessed by aqueous angiography.
Methods
Enucleated human eyes (14 total from 7 males and 3 females [ages 52-84]) were obtained from an eye bank within 48 hours of death. Eyes were oriented by inferior oblique insertion, and aqueous angiography was performed with indocyanine green (ICG; 0.4%) or fluorescein (2.5%) at 10 mm Hg. With an angiographer, infrared and fluorescent images were acquired. Concurrent anterior segment optical coherence tomography (OCT) was performed, and fixable fluorescent dextrans were introduced into the eye for histologic analysis of angiographically positive and negative areas. Experimentally, some eyes (n = 11) first received ICG aqueous angiography to determine angiographic patterns. These eyes then underwent trabecular micro-bypass sham or stent placement in regions initially devoid of angiographic signal. This was followed by fluorescein aqueous angiography to query the effects.
Results
Aqueous angiography in human eyes yielded high-quality images with segmental patterns. Distally, angiographically positive but not negative areas demonstrated intrascleral lumens on OCT images. Aqueous angiography with fluorescent dextrans led to their trapping in AHO pathways. Trabecular bypass but not sham in regions initially devoid of ICG aqueous angiography led to increased aqueous angiography as assessed by fluorescein (P = 0.043).
Conclusions
Using sequential aqueous angiography in an enucleated human eye model system, regions initially without angiographic flow or signal could be recruited for AHO using a trabecular bypass stent.
MeSH Terms
Shields Classification
Key Concepts5
Trabecular bypass stents, but not sham procedures, in regions initially devoid of indocyanine green (ICG) aqueous angiography signal led to increased aqueous angiography as assessed by fluorescein (P = 0.043) in human enucleated eyes.
Regions initially without angiographic flow or signal could be recruited for aqueous humor outflow using a trabecular bypass stent in an enucleated human eye model system.
Aqueous angiography in human enucleated eyes yielded high-quality images with segmental patterns.
Distally, angiographically positive but not negative areas demonstrated intrascleral lumens on OCT images in human enucleated eyes.
Aqueous angiography with fluorescent dextrans led to their trapping in aqueous humor outflow pathways in human enucleated eyes.
Related Articles5
Functional Assessment of Aqueous Humor Outflow by Aqueous Angiography in Primary Open Angle Glaucoma.
Cross-Sectional StudyAnterior segment imaging in minimally invasive glaucoma surgery - A systematic review.
Systematic ReviewAutomated Gonioscopy Assessment of XEN45 Gel Stent Angle Location After Isolated XEN or Combined Phaco-XEN Procedures: Clinical Implications.
Cross-Sectional StudyStructural and functional imaging of aqueous humour outflow: a review.
ReviewK-RIM (Corneal Rim) Angle Surgery Training Model.
Basic ScienceIs this article assigned to the wrong chapter(s)? Let us know.