Role of Static and Dynamic Ocular Biometrics Measured in the Dark and Light as Risk Factors for Angle Closure Progression.
Austin Cho, Benjamin Y Xu, David S Friedman, Paul J Foster, Yu Jiang, Anmol A Pardeshi, Yuzhen Jiang, Tin Aung, Mingguang He
Summary
Static parameters measured in the light are as predictive, and possibly more so, of angle closure progression as those measured in the dark.
Abstract
PURPOSE
To assess the role of static and dynamic ocular biometric parameters measured in the dark and light for predicting progression of primary angle closure suspect (PACS) to primary angle closure (PAC).
DESIGN
Retrospective cohort study using prospective randomized controlled trial data from untreated, control eyes.
METHODS
Zhongshan Angle Closure Prevention Trial subjects underwent anterior segment optical coherence tomography (AS-OCT) imaging in the dark and light. Static biometric parameters were measured, consisting of angle, iris, lens, and anterior chamber parameters. Dynamic change parameters were calculated by subtracting light measurements from dark measurements. Cox proportional hazards regression models were developed to assess risk factors for PACD progression.
RESULTS
A total of 861 eyes of 861 participants were analyzed (36 progressors). On univariable analysis, TISA500 measurements in the light and dark were associated with progression (P < .001), whereas dynamic change parameters were not (P ≥ .08). In the primary multivariable model, older age (hazard ratio [HR] = 1.09 per year), higher intraocular pressure (IOP) (HR = 1.13 per mm Hg), and smaller TISA500 in the light (HR = 1.28 per 0.01 mm) were significantly associated with greater risk of progression (P ≤ .04). Dark TISA500 had similar significance (HR = 1.28, P = .002) when replacing light TISA500. Risk of progression was more predictive among eyes in the lowest quartile of light TISA500 measurements (HR = 4.56, P < .001) compared to dark measurements (HR = 2.89, P = .003).
CONCLUSION
Static parameters measured in the light are as predictive, and possibly more so, of angle closure progression as those measured in the dark. Ocular biometrics measured under light and dark conditions may provide additional information for risk-stratifying patients for angle closure progression.
More by Austin Cho
View full profile →Biometric Risk Factors for Angle Closure Progression After Laser Peripheral Iridotomy.
Refractive Error and Anterior Chamber Depth as Risk Factors in Primary Angle Closure Disease: The Chinese American Eye Study.
Short-Term Ocular Biometric Changes as Predictors of Long-Term Angle Closure Progression.
Top Research in IOP & Medical Therapy
Browse all →The Complications of Myopia: A Review and Meta-Analysis.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Treatment Outcomes in the Primary Tube Versus Trabeculectomy Study after 1 Year of Follow-up.
In the Knowledge Library
Discussion
Comments and discussion will appear here in a future update.